Descargar Imprimir esta página

Oase BioMaster 850 BioMaster Thermo 250 Instrucciones De Uso página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

- EN -
Assembling the outlet assembly
The outlet assembly can either be installed using the spray bars or the water distributor
How to proceed:
N
• Assembling the outlet assembly using spray bars
1. Connect the two spray bars via the connecting piece.
2. Seal spray bar assembly with cover cap.
3. Attach spray bars to adjustable outlet adapter via elbow.
4. Screw locking nut onto adjustable outlet adapter.
5. Connect the clips to the suction cups. These will be used to attach the outlet assembly to the tank .
6. Attach the clips at the spray bars and adjustable outlet adapter as shown.
7. Use a coin or a flat head screwdriver to turn the flow regulator on the outlet adapter to MAX.
• Assembling the outlet assembly using the water distributor nozzle
1. Attach the water distributor nozzle to adjustable outlet adapter via elbow.
2. Screw locking nut onto adjustable outlet adapter.
3. Connect the clip to the suction cup. This will be used to attach the intake assembly to the tank.
4. Attach the clips at the adjustable outlet adapter as shown.
5. Use a coin or a flat head screwdriver to turn the flow regulator on the outlet adapter to MAX.
Connecting the tubing
The procedure is identical for the inlet (IN) and outlet (OUT).
Prerequisite: Install the unit. Install the unit next to or under the aquarium. Note the maximum head height.
(→ Technical data P. 21)
How to proceed:
O
1. Fasten the inlet assembly and outlet assembly in the aquarium using suction cups.
2. Shorten the tubing to the required length.
– Choose the length so that the tubing cannot kink in the intended installation position.
3. Screw the locking nut onto the inlet and outlet connection unit on the unit head.
4. Push the tubing onto the connection unit and turn the locking nut counter-clockwise to fix the tubing in
place.
5. Push the other end of the tubing onto the inlet/outlet adapter of the inlet assembly/outlet assembly and
turn the tubing locking nut counter-clockwise to fix the tubing in place.
COMMISSIONING/START-UP
For initial start-up or after thorough cleaning, it is necessary to expel air from the filter system. When the filter
unit, inlet assembly and tubing are free of trapped air, the pump can convey the water by itself through the
filter system. (→ Expelling air from the filter system P.14)
12
BioMaster 250/350/600/850, BioMaster Thermo 250/350/600/850
Outlet assembly using spray bars
- EN -
Outlet assembly using water
distributor nozzle
13

Publicidad

loading

Este manual también es adecuado para:

Biomaster 350Biomaster 600Biomaster 250Biomaster thermo 350Biomaster thermo 600Biomaster thermo 850