8. Disconnect the Blower Motor and Check Valve - Remote
NOTICE: This section applies only to installations in which the blower motor and check valve are
being relocated from the shipping position on the support board.
NOTICE: Do not cut the bath harness (pipes) for this installation. Cutting the bath harness will void
the warranty.
NOTICE: The check valve must be relocated with the blower motor.
Removing the Blower Motor
Disconnect the blower motor electrical plug from the control.
Remove any cable ties that support the blower motor cord.
Remove the retaining screw holding the air harness on the blower motor discharge. Do not discard
the screw at this time.
Remove the four blower motor mounting screws from the blower adapter baseboard. Keep these
screws.
While restraining the tee with one hand, slide the blower motor away from the tee.
Remove the blower motor from the bath.
Remove the Check Valve
Remove the upper retaining screw at the check valve. Do not discard the screw at this time.
Remove the check valve and attached PVC elbow from the bath.
Prepare the Site for the Blower Motor and Check Valve
NOTE: Refer to the "Before You Begin" section for detailed requirements for the blower motor relocation.
Prepare the site where the blower motor will be installed. The site must be within 15' (4.5 m) of the
bath.
As appropriate, install an access panel to service the blower motor.
As appropriate to the installation, prepare the routing paths for the PVC piping and the new blower
motor power cable. Follow all applicable building, fire, plumbing, and electrical codes.
1035472-2-G
Blower Motor
Mounting Screws
Cover
Junction
Box
Baseboard
14
Elbow
Check
Valve
Screw
Control
To Blower Motor
Blower Motor
Electrical Plug
Kohler Co.