DISPLAY DATA
DESCRIPTION
Fot 1
PHOTO 1 input
APCh
- Input is available for the connection of the photocell
no
- Not available
Fot 2
PHOTO 2 input
CFCh
- Photocell is active in closing and also when the gate is still
no
- Not available
Ch
- Photocell is active during the closing
tESt
Test of safety devices
no
- Function not active
Foto
- Test enabled only for photocells
CoSt
- Test enabled only for safety edges
Ft.Co
- Test enabled either for photocells or for safety edges
CoS1
Border 1 input (fixed border)
no
- Input disabled (the control unit ignores it)
rESi
- Input enabled for conductive rubber ribbons
StAn
- Input enabled for standard safety ribbons with normally closed contact
CoS2
Border 2 input (mobile border)
no
- Input disabled (the control unit ignores it)
rESi
- Input enabled for conductive rubber ribbons
StAn
- Input enabled for standard safety ribbons with normally closed contact
FC.En
no/Si
End of stroke inputs
ASM
0.5" ÷ t.AP
Anti-skid
no
- Function disabled
SEnS
no ÷ 4.0A
Obstacle sensor level
S.din
no/Si
Dynamic regulation of the obstacle sensor threshold
MFC
0.0" ÷ 2.0'
Allowance on the end stroke
Cont
Counter viewing
tot.
- Total number of completed cycles (views in thousands or in units)
Man
- Number of cycles before the next request for service (such a number
APPr
Automatic learning of the operation time
no
- Function disabled
Go
- Start up of the automatic learning procedure
FinE
End of programming
no
- It does not exit from the program menu
Si
- It exits from the program menu by storing the setup parameters
City6 FUNCTION TABLE
has been rounded off to hundreds and it can be set up on 1000-step;
in case it is set up on 0, the request will be disabled and no will be viewed)
35
MEMO
DEFAULT
DATA
no
CFCh
no
no
no
Si
1.0"
no
tot
no
no