3
Trim Installation
A.
3
4
3
5
8
Escutcheon Installation
Note: On models (T27T876 & T27T976) install the
valve seal (8) onto the back of escutcheon (5).
For finished walls up to 1 1/8". Install trim sleeve
(1) over valve cartridge (7) and bonnet. Secure
backplate (2) to rough-in body using 4 screws (3)
provided.
Note: Be sure backplate is oriented front side
forward and markings are visible.
Holding escutcheon (5) in place, thread trim nut (4)
onto diverter sleeve (6).
Note: For thick wall installations, order
installation kit RP90544 to support finished wall
thickness up to 2 1/8".
On rough or uneven surfaces it is necessary to
apply caulk around the backplate (2) to supplement
the seal. Do not caulk the drip notch in the bottom of
the backplate (2). Do not caulk the escutcheon (5).
Installation and Adjustment of the Temperature Knob. Failure to do so may cause injury.
C.
3
2
1
4
Adjust temperature limit stop
Turn on water supplies; LET THE WATER RUN AT
BOTH FULL HOT AND FULL COLD TO ENSURE
THE WATER IS RUNNING AS HOT/COLD AS
POSSIBLE. Place a thermometer in a plastic
tumbler, and hold the tumbler in the water stream.
Place the temperature knob (1) onto the splines
(2), then rotate the temperature knob counter-
clockwise until you achieve your maximum desired
temperature from the outlet (not more than 120°
or the lower temperature mandated by your local
plumbing code).
If max temperature is not achieved before limit
All manuals and user guides at all-guides.com
6
2
7
1
Volume Handle Installation
Install valve handle (1) over cartridge (4), screw in
set screw (2) using a allen wrench.
Place set screw cover (3) over set screw and apply
pressure until cover is properly seated.
5
Installation
B.
3
1
2
4
stop (3) on temperature knob (1) meets the limit
stop (4) on the volume control handle. Remove
the temperature control knob (1) from splines (2).
Rotate temperature control knob (1) clockwise.
Place temperature control knob (1) back onto
splines (2) and continue to rotate counter-clockwise
until maximum desired temperature is achieved.
Remove the temperature knob (1) and replace onto
thesplines (2), making sure that the temperature
knob limit stop (3) hits against the volume handle
limit stop (4) as shown.
4
3
102019 Rev. A