The value of all menu items can be brought to a standard value (see
final recap table) by means of only one command. There are two sets
of values available:
AntE
Values for a two-leaf gate equipped with a lock.
SCor
Values for a one-leaf sliding gate without lock.
After loading default values, the other menu items can be scrolled and
each parameter can be changed; exit from default menu will cause the
automatic selection of the next item.
Leaf 1 opening time
Motor 1 will be operated for the setup time in the opening phase;
in case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
Leaf 2 opening time
Motor 2 will be operated for the setup time in the opening phase;
In case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
WARNING: if motor 2 is not connected, this time must be set to
zero; in this circumstance, the control unit will not consider all
configurations of motor 2 and door phase difference times as well.
Partial opening time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will
open leaf 1 only, for a shorter time. Max allowed time to be setup is
t.AP1.
Leaf 1 closing time
Motor 1 will be operated for the setup time in the closing phase;
In case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
To avoid that the door does not close completely, we recommend to
setup a longer time than t.AP1 opening time.
32