Descargar Imprimir esta página

Rocal CITY X1300 Manual De Instrucciones página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1. SPECIFICATIONS
1.1 Technical specifications
Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O2
Particle concentration
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Flue duct
Ø Air inlet
Front safety distance
Side safety distance
Back safety distance
Base safety distance
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate No.:
1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body
2. Flue liner connector
3. Body of the ceiling plate
4. Tool for handling registers and opening door
5. Upper baffle to limit the draught
6. Aluminium ring to connect
7 Heat-resistant glove
8 Cleaning cloth
9. Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
10. Metal clamp
11. Bag with metallic anchors
12. Heat-resistant spray paint for touch-ups
13. Bag with screws and anchors
14. Fixative of the aluminium ring
15. Exterior air inlet cover
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Wall. Make sure the wall where the appliance will be placed is able to support the weight of the device. If not, you will need a load
spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
Value
11-13 Pa
3,6 kg/h
9,5 - 17 kW
28,72 mg/Nm
148 kg
200 mm
350 mm
4000 mm
180 mm
120 mm
1000 mm
1000 mm
500 mm
300 mm
177º C
INTERMITTENT
NOT SHARED
NATURAL WOOD
12-20% - two years under cover
17/16198-3248 | 17-16198-3250
13 g/s
85 %
14 kW
0,08%
3
13 Pa
3,5 kg
2018
9

Publicidad