RECOMMENDED LOAD WORK
∅ anchorage
Minimum embedding H
(mm)
10
Rawplug
Screw size
size (mm)
(mm)
10x80
M8x80
2.3 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations. This Flue liner should not be shared with other devices (see Table 1.1
Technical specifications).
2.4 Type of appliance. This fireplace is exempt, so it doesn't need any revetment.
2.5 Security insulating and safety distances.
Any fragile or flammable element, textiles, electronic devices, wood, wallpaper, glass, chalk paper, etc., must be separated from the
device observing the minimum distance described in Table 1.1 Technical specifications. Special attention should be paid to equipment
installed in contact with wood or similar: we must prevent or avoid the possibility of hot air impacting directly on the wood: in such
case, it shall be insulated accordingly.
2.6 Air supply. Air should be provided to the room where the appliance is installed. This is especially relevant when outside air is not
used and also when the door is opened for reloading with logs. This entry cannot be less than 225 cm
operation with other ventilation devices and / or heating such as exhaust fans, heat pumps, etc. In these cases, the extraction must
be compensated with a corresponding air entry from outside.
2.7 Changes to the device. Any intended change to the equipment must be authorized in writing by Manufacturas Rocal, S.A. We
also recommend using only original spare parts or parts recommended by Manufacturas Rocal, S.A.
3. INSTALLATION
3.1 Installation process. To proceed with the installation, follow the steps outlined in Section III of the ANNEXED document.
WARNING: The second piece of the deflector plate (part 8 of the section of the document ANNEX II) should only place in case of
excess draught, follow the steps to install it: " C.7".."C.15".
. USE AND OPERATION
4
4.1 Fuels authorized by the manufacturer. The appliance should not be used as an incinerator and the use of fuels other than
those authorized by the manufacturer are prohibited, including lighting liquids or gels. Only natural wood logs are authorized as fuel
and it is not advisable to use resinous woods.
CAUTION:
- The maximum load allowed by the manufacturer, the measurements of the logs and the height of the
reload must be respected.
- Do not touch or manipulate any part of the appliance when in operation without a protection glove.
4.2 Pilot fire lighting. For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum load allowed
by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed inside (such as gloves,
spray paint ...)
4.3. Combustion control. The appliance has mechanisms to regulate combustion.
4.3.1. Primary register. The primary register is used to control the air entering the combustion chamber through the base of the fire,
through the fire grate. The primary register should be used mainly for lighting and, if necessary, to aid combustion. To locate the
register control handle and to know how to use it see picture "C.3" of the ANNEXED document.
4.3.2. Secondary register. The secondary register is used to control the air entering the combustion chamber from the top. The
secondary register is used as combustion intensity adjustment. To locate the register control handle and to know how to use it see
picture "C.4" of the ANNEXED document.
4.4 Fire lighting. To light the fire, use suitable materials for this purpose, such as heat pads, paper, dry and thin branches. DO NOT
USE GASOLINE, SOLVENTS OR ALCOHOL. To see the correct position, see picture "C.5" of the ANNEXED document, then light
he fire using a suitable material. Once the fire is lit keep the door and the registers open for a reasonable time to prevent condensation
on the door. When the apparatus is hot enough close the door, adjust the primary register to avoid excessive combustion and control
the intensity of fire by the child record.
IMPORTANT:
-The interior vermiculite parts SHOULD NOT RECEIVE IMPACTS when refueling is performed.
If any of these parts crack, but is properly set in its place, THE PROPER OPERATION OF THE
APPLIANCE SHALL NOT BE ALTERED AND THERE IS NO POTENTIAL RISK. The equipment can be
used normally. These cracks do not entail any manufacturing defect so they do not fall under
guarantee.
Extraction strength
(mm)
50
TECHNICAL DETAILS
∅ Bit
Min. drill
depth (mm)
(mm)
10
(Quality 6.8, concrete 250 kg/cm
(kg)
350
Thickness to fix
max. (mm)
85
30
2
)
Shear strenght
(kg)
450
Tightening torque
(kg x cm)
150
2
. Also note the simultaneous
10