The electronic control unit ZED24 can be used to control 1 or 2 motors with a power not exceeding 120W+120W.
The following types of installation are possible:
A)
1 Motor ZED24 with built-in control unit: In fig.1, with reference to the "A" general scheme, connect the accessories as
indicated in the "C" diagram.
1 Motor ZED24 with built-in control unit and one motor ZED24 without control unit: In fig. 1, taking as a reference the "A"
B)
and "B" general diagrams, connect the accessories as per "C" diagram and connect the two motors as indicated in the "D"
diagram shown in Fig. 2.
1 Control unit ZED24 fitted to wall and two motors ZED24 without control unit: In fig. 1, taking as a reference the "A" and
C)
"B" general diagrams, connect the accessories as per "C" diagram and connect the two motors as indicated in the "E" diagram
shown in Fig. 2.
IMPORTANT: Should two motors be used, connect the limit switches of one single motor to the control unit.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be detached, or adequately insulated by an additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-Switches are the required ones.
f) Normally Closed inputs which are not in use should be short-circuited 230VAC – keep to phase/neutral).
Terminal No. Function
1-2
Power supply
3-4
Flashing light
5-6
Light, Motor 2
7
COM
8
SWO
9
SWC
10
STOP
11
PHOT
12
OPEN
13
CLOSE
14
Step-by-Step
15-16
Motor 1
17-18
Motor 2
19-20
24 Vac
21-22
SCA
23-24
COSTA
25-26
Aerial
0-24-VMOT
Secondary
L1-N1
Primary
J3
Radio receiver
8
ZED24 Control unit
GENERAL WARNINGS
INPUT/OUTPUT FUNCTIONS
ZED24 Control Unit
Description
Input, 230VAC 50Hz (1-Phase/2-Neutral)
Connection of flashing light, 24Vac 40W max.
Connection to the courtesy light of motor 2
(only when 2 motors are in use)
Common for limit switch and all control inputs.
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input, STOP push button (N.C. contact)
Input, connection to safety devices, N.C. contact
(e.g. Photocells)
Input, OPEN push button (N.O. contact)
Input, CLOSE push button (N.O. contact)
Input, step-by-step push button (N.O. contact)
Connection to motor 1 (15+/16-)
Connection to motor 2 (15+/16-)
To be used only when 2 motors are in use
Output, power supply of accessories, 24Vac/1A max.
IMPORTANT: If the battery charger board CB.24V is installed, the output (without mains
power connected) has a 24Vdc polarised voltage.
Make sure the devices are correctly connected (i.e. 19:+24Vdc - 20:-24Vdc).
Free contact, N.O. for open door warning light.
Input, safety edge contact
Resistive edge: Closed "DAS" jumper
Mechanical edge: Open "DAS" jumper
If the safety edge is activated in the opening phase, the gate stops.
In the closing phase, the gate stops and the performs a movement reversion (opens) for 3s.
Connection to the radio receiver card of the aerial (25-screen/26-signal).
Connection, winding of secondary transformer
Connection, winding of primary transformer
Connector for radio receiver.