Logic
Definition
Closing limit switch
PRESS SWC
pressure
ICE
Ice feature
1 MOT. O N
1 motor active
OPEN IN OTHER
Open in other
direction
DIRECT.
Configuration of
SAFE 1
safety input SAFE 1.
Configuration of
SAFE 2
safety input SAFE 2.
Configuration of
SAFE 3
safety input SAFE 3.
Configuration of
SAFE 4
safety input SAFE 4.
Configuration of
SAFE 5
safety input SAFE 4.
Configuration of
SAFE 6
safety input SAFE 6.
Configuration of
IC 1
command input IC 1.
Configuration of
IC 2
command input IC 2.
Configuration of
IC 3
command input IC 3.
Configuration of
IC 4
command input IC 4.
36 -
THALIA P
INSTALLATION MANUAL
Cross out
Default
setting
used
0
0
1
0
0
1
0
0
1
0
0
1
0
1
0
72
2
3
4
5
6
6
74
7
8
0
2
77
1
2
4
79
3
4
0
5
79
6
6
7
84
0
0
61
1
2
4
62
3
4
2
64
5
3
6
65
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing
limit switch must be adjusted accurately (Fig.g Ref.B).
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor
interpreting this as an obstacle.
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as
the mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the
closing limit switches to trip slightly earlier (Fig.g Ref.A).
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower
than the value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
This feature is useful when dealing with installations running at low temperatures.
WARNINg: once this feature has been activated, you will need to perform an autoset opening and
closing cycle.
Both motors active (2 leaves).
Only motor 1 active (1 leaf ).
Standard operating mode (See Fig.g Ref. C).
Opens in other direction to standard operating mode (See Fig. g Ref.D)
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2.
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Start E.
Input configured as Start I.
Input configured as Open.
Input configured as Close.
Input configured as Ped.
Input configured as Timer.
Input configured as Timer Pedestrian.