1. SPECIFICATIONS
1.1 Tehnical specifications
Parámetro
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Efficiency
Nominal output
Power range
Average CO concentration at 13% of O2
NOx concentration at 13% of O2
OGC concentration at 13% of O2
Particle concentration at 13% of O2
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Ø Air outlet
Fireplace safety distances
Fireplace safety distances
Fireplace safety distances
Fireplace safety distances
Fireplace room ventilation
Cableado eléctrico de conexión
Flujo aire turbinas (unidad)
Potencia turbinas (unidad)
Distancia seguridad mín. a las salidas de aire
Temperatura media de humos
Tipo de combustión
Conducto
Combustible
Humedad leños combustible
Año Certificación
Nº de Certificado
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. Heat-resistant spray paint for touch-ups.
3. Fire grate.
4. Heat-resistant glove.
5. 2x Outlet hot air connector (ARc 76 LD, ARc 76 LD +Plus 180, ARc 76 LI, ARc 76 LI +Plus 180). 4x Outlet hot air connector
(ARc 96 LD, ARc 96 LI)
6. Cleaning cloth
7. Exterior air inlet kit. (Exterior air inlet connector, connector support, tubular joint, metallic anchor, screws and nuts)
8. Tool for handling registers and opening door.
9. Bag with screws.
10. Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
11. +Plus 180 (ARc 76 LD +Plus 180, ARc 76 LI +Plus 180)
12. Draught limiter
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
ARc 76 LD
ARc 76 LI
11-13 Pa
2,74 kg/h
8,77 g/s
84 %
9,7 kW
6,5 – 11 kW
0,09 %
100,17 mg/Nm
93,34 mg/Nm
27,68 mg/Nm
12 Pa
136 kg
4 kg
200 mm
400 mm
4000 mm
180 mm
100 mm
120 mm
(back)
200 mm
(side)
200 mm
(glass side)
1000 mm
(frontal)
1000 mm
(entry - exit)
450 cm
204ºC
2019
19/20678-1854-1/2
Modelo
ARc 76 LD +Plus 180
ARc 76 LI +Plus 180
11-13 Pa
2,8 kg/h
10,8 g/s
77,3 %
9,4 kW
6,5 – 11 kW
0,08 %
3
104 mg/Nm
3
66 mg/Nm
3
16,4 mg/Nm
11,2 Pa
153,9 kg
4 kg
200 mm
400 mm
4000 mm
180 mm
100 mm
120 mm
200 mm
200 mm
1000 mm
1000 mm
2
450 cm
Silicone hose 3*wire of 1.5 mm
135 m
20 W
250 mm
270 ºC
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20 % - two years under cover
2019
1880-CPR-014-19
ARc 96 LD
ARc 96 LI
11-13 Pa
2,86 kg/h
11,86 g/s
81 %
10,2 kW
7 – 12 kW
0,067 %
3
100 mg/Nm
3
57 mg/Nm
3
11 mg/Nm
11,5 Pa
187 kg
200 mm
500 mm
4000 mm
180 mm
100 mm
120 mm
200 mm
200 mm
700 mm
1500 mm
2
450 cm
2
3
/h
293,7 ºC
2022
1880-CPR-026-22
3
3
3
5 kg
2
9