A、When the full water lasts for 3 seconds , the controller stops working and all outputs are turned
off. The full water indicator is on (FULL, the buzzer sounds 15 rings. Press any key, the bee The
alarm will stop immediately.
B、When the full water fault is removed, the original machine's operating status is restored (the
compressor must be protected by 3 minutes)
6、Defrost function:
A、When it is in defrosting, the compressor is turned off, the fan is defrosted by high winds, and the
defrost indicator lights up (DEF).
B、When the room temperature is less than or equal to 16°C, the temperature of the coil is not
detected. According to the room temperature action, it is as follows::
Room temperature <5°C, the controller stops;
When 5°C ≤ room temperature ≤ 12°C, the compressor is running for 30 minutes and the
defrost is stopped for 10 minutes;
When 12°C< room temperature ≤ 16°C, the compressor is running for 45 minutes and the
defrost is stopped for 10 minutes
C、When the room temperature is greater than 16°C, the temperature of the coil is detected, and
the operation is performed according to the temperature of the coil, as follows:
When the compressor is running for 30 minutes, the coil temperature is detected. If the coil
temperature is ≤ 1°C, the defrosting is stopped for 10 minutes.
7、Compressor delay protection:
A、Every time the boot compressor is allowed to start immediately;
B、After the compressor is shut down, start it again, with at least a 3-minute interval.
9、WIFI
A、Long press WIFI button 5S to enter WIFI factory configuration mode;
B、WIFI light: extinguished indicates that the dehumidifier is not connected to the WIFI; long light
indicates that the dehumidifier has successfully connected to the WIFI;
C、The mobile phone APP through WIFI may realize all the functions related to the dehumidification
machine.
WATER TANK DRAIN
When the drainage tank is full, the tank full indicator light will turn on, the operation will stop
automatically and the buzzer will beep 15 times to alert the user, that the water need to be emptied
from the drainage tank.