Outdoor unit:
Outdoor side heat exchanger of air conditioner/heat pump: air
Indoor side heat exchanger of air conditioner/heat pump: water
Type: compressor driven vapour compression
Driver of compressor:electric motor
Indication if the heater is equipped with a supplementary heater: yes
Parameters shall be declared for the average heating season
Item
Parameters shall be declared for:
Indoor heat exchanger:
Rated heating capacity
Declared heating capacity for part load at indoor temperature
20 °C and outdoor temperature Tj
Tj = – 7°C
Tj = 2°C
Tj = 7°C
Tj = 12°C
Tj = bivalent temperature
Tj = operating limit
Bivalent temperature
heating/Average
heating/Warmer
heating/Colder
mode(heating)
Supplementary capacity
Capacity control
Reference annual heating
demand
Annual energy consumption
Contact details
Technical parameters
AHW-060HCDS1
Symbol
Value
Unit
P
5.37
kW
rated,h
Pdh
4.7
kW
Pdh
3.0
kW
Pdh
2.0
kW
Pdh
2.0
kW
Pdh
4.7
kW
Pdh
4.5
kW
Tbiv
-7
°C
Tbiv
—
°C
Tbiv
—
°C
Cd
0.9
Power consumption in modes other than 'active mode'
P
0.010
kW
OFF
P
0.011
kW
TO
Supplementary heater
P
0.805
kW
SUP
Variable
Q
11032
kWh
H
Q
3312
kWh
HE
Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd
No. 218, Qianwangang Road, Economic and Technological Development Zone, Qingdao, China
Indoor unit:
Item
Heating
Medium temperature application
Variable outlet
Seasonal space heating
temperature 20 °C and outdoor temperature Tj
Tj = – 7°C
Tj = 2°C
Tj = 7°C
Tj = 12°C
Tj = bivalent temperature
Tj = operating limit
Operating limit temperature
heating/Average
heating/Warmer
heating/Colder
Standby mode
Crankcase heater mode
Type of energy input
Other items
Sound power level , indoor/
outdoor measured
Global warming potential
39
TECHNICAL PARAMETERS
AH -060HCDSAA
Symbol
Value
η
130
s,h
COPd
2.04
COPd
3.21
COPd
4.34
COPd
7.24
COPd
2.04
COPd
1.75
Tol
-10
Tol
—
Tol
—
P
0.010
SB
P
0.001
CK
Electric
2700
LWA
42/62
GWP
675
kgCO
unit
%
—
—
—
—
—
—
°C
°C
°C
kW
kW
3
m
/h
dB(A)
eq.
2