Roll the blower unit 90° so that fan blade openings
5
are facing out the back of the oven.
Before Rolling
Back of
Oven
Locate the two "knockout" plates, on the rear oven
6
panel, near the top of the oven.
Using tin snips, carefully cut the web area from the
two holes side-by-side (that secure the knockouts to
the oven). Cut all four webs on both rear knockouts;
this will allow the ventilation fan airflow to exhaust
out the rear of the oven.
CAUTION:
edges from the openings after removing the
knockout plates.
Oven Rear Panel
7 Place the blower unit back into the opening.
AFTER: Fan Blade
Openings Facing
Back
End B
CAUTION:
the blower unit wiring. Make sure the wires
are not pinched.
NOTE: The blower unit exhaust openings should
match exhaust openings on rear of oven.
Installation Instructions
After Rolling
Back of
Oven
Be sure to trim the sharp
Snip all 4 webs
on each knockout
panel and remove
the metal knockouts
for rear airflow.
End A
Do not pull or stretch
8
Replace the blower plate in the same position
as before with the screws.
9 Insert the tabs on each side of the damper
into the holes at the inside rear of the adaptor.
Attach the exhaust adaptor to the rear of the oven
10
by sliding it into the guides at the top center of the
back of the oven.
Exhaust Adaptor
Slide exhaust
adaptor into
guides on
oven rear.
Push in securely until it is in the lower locking tabs.
Take care to assure the damper hinge is installed
so that it is at the top and that the damper swings
freely.
Secure the exhaust adaptor to the oven with
11
the two bronze metal screws provided.
17
Blower Plate Screws
Blower Plate
Back of Oven
Exhaust
Adaptor
Damper
(hinge side up)
Screws
Back of Oven
Locking
Tabs
Guides