IMPORTANT SAFETY INSTRUCTIONS
See Electrical Requirements for proper outlet installation
requirements. The installer must perform a ground
continuity check on the power outlet box before beginning
the installation to ensure that the outlet box is properly
grounded. If not properly grounded, or if the outlet box does
not meet electrical requirements noted (under ELECTRICAL
REQUIREMENTS), a qualified electrician should be employed
to correct any deficiencies.
CAUTION:
mounting surface must be capable of supporting the
cabinet load, in addition to the added weight of this
63-85 pound product, plus additional oven loads of
up to 50 pounds or a total weight of 113–135 pounds.
CAUTION:
product cannot be installed in cabinet arrangements
such as an island or a peninsula. It must be mounted
to BOTH a top cabinet AND a wall.
NOTE: For easier installation and personal safety, it is
recommended that two people install this product.
IMPORTANT—PLEASE READ CAREFULLY. FOR PERSONAL
SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED
TO AVOID SEVERE OR FATAL SHOCK.
ELECTRICAL REQUIREMENTS
120 V Models
This product requires a three-prong grounded outlet.
Product rating is 120 volts AC, 60 Hertz, 15 amps,
and 1.70 kilowatts. This product must be connected
to a supply circuit of the proper voltage and frequency.
Wire size must conform to the requirements of the
National Electrical Code or the prevailing local code
for this kilowatt rating. The power supply cord and
plug should be brought to a separate 15 to 20 ampere
branch circuit single grounded outlet. The outlet box
should be located in the cabinet above the oven.
The outlet box and supply circuit should be installed
by a qualified electrician and conform to the National
Electrical Code or the prevailing local code.
Installation Instructions
CAUTION:
For personal safety, remove
house fuse or open circuit
breaker before beginning
installation to avoid severe
or fatal shock injury.
For personal safety, the
For personal safety, this
You should have the wall receptacle and circuit checked
by a qualified electrician to make sure the receptacle is
properly grounded.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM, OR
REMOVE ANY OF THE PRONGS FROM THE POWER CORD.
DO NOT USE WITH AN EXTENSION CORD.
120 V Models
The power cord of this appliance is equipped with
Ensure proper
ground exists
before use.
240 V Models
The wall outlet receptacle recommended for this
NEMA 14–30R
Wall Receptacle
Ensure proper
ground exists
before use.
240 V Models
This product requires a four-prong grounded outlet.
Product rating is 120/208 or 120/240 volts, 60 Hertz,
30 amps and 6.5 kilowatts. This product must be
connected to an individual properly grounded branch
circuit, protected by circuit breakers or time-delay
fuses. Wire size must conform to the requirements of
the National Electrical Code or the prevailing local code
for this kilowatt rating. The outlet box should be located
in the cabinet above the oven. The outlet box and
supply circuit should be installed by a qualified
electrician and conform to the National Electrical Code
or the prevailing local code.
3
a three-prong (grounding)
plug which mates with
a standard three-prong
(grounding) wall receptacle
to minimize the possibility
of electric shock hazard
from this appliance.
Where a standard
two-prong wall receptacle
is encountered, it is very
important to have it
replaced with a properly
grounded three-prong wall
receptacle, installed by a
qualified electrician.
appliance is NEMA #14–30R
and accepts the four-prong
grounded plug of this
appliance.