F18...
Burner Injector 1/100 mm
Pilot Injector
Consumption
Primary air h=mm
F25...
Burner Injector 1/100 mm
Pilot Injector
Consumption
Primary air h=mm
F2/18...
Burner Injector 1/100 mm
Pilot Injector
Consumption
Primary air h=mm
F2/25...
Burner Injector 1/100 mm
Pilot Injector
Consumption
Primary air h=mm
DISPOSALS FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS
Our appliances are tested and regulated with liquid gas /see plate).
The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see table of "burners" technical
data).
SUBSTITUTING THE NOZZLE IN THE MAIN BURNER
•
In order to operate inside the appliance, it is necessary to empty the water container.
•
Remove the front fixing screws from the panel, remove the start up cable from the piezoelectric ignition device.
•
Unscrew the nut and lower the air regulation stirrup.
•
Using a suitable spanner, unscrew the nozzle and substitute it with the right one (see the "Technical Data" table).
•
Put the air regulation stirrup into its original position.
SUBSTITUTING THE NOZZLE IN THE PILOT BURNER
The flame of the pilot burner has fixed air.
The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the
fitting and substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.
Important!
After having effected the conversion to another type of gas, it is necessary to update the data plate, indicating the type
of gas for which the appliance has been converted.
•
The appliance contains the instructions necessary for use.
•
Check the appliances for gas leaks.
•
Examin the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
•
Check the lighting and flame of the main burner.
•
We urge the user to follow the instructions when using the appliance.
GB
TABLE OF "BURNERS" TECHINCAL DATA
12.68 kWh/KG
G30
BUTANE
28 mbar
3 x115
30
kg/h 1,183
25
4 x115
30
kg/h 1,577
25
6 x115
30
kg/h 2,366
25
8 x115
30
kg/h 3,155
25
CHECKING FUNCTIONING
IE
12.87 kWh/KG
G31
PROPANE
37 mbar
3 x 115
30
kg/h 1,166
25
4 x 115
30
kg/h 1,554
25
6 x 115
30
kg/h 2,331
25
8 x 115
30
kg/h 3,108
25
33
3
9.45 kWh/m
st.
G20
NATURAL GAS
20 mbar
3 x 170
51
3
m
st./h 1,587
25
4 x 170
51
3
m
st./h 2,116
25
6 x 170
51
3
m
st./h 3,175
25
8 x 170
51
3
m
st./h 4,233
25