Cleaning and Storage
This device must be kept clean and free
of contaminants. Periodically clean the
exterior of the device and wipe the lifeline
using a damp cloth and mild detergent.
When not in use, equipment shall be stored
in a manner as to preclude damage from
environmental factors, such as temperature,
light, UV, excessive moisture, oil, chemicals
and their vapors, or other degrading
elements. The lifeline should be fully
retracted into the device when not in use.
TABLE 2: ANSI Z359.14-21 and CSA Z259.2.2 Inspection Requirements
Application
Type of Use
Examples
Infrequent
Rescue & con-
to Light
fined space,
Factory
maintenance
Moderate to
Transportation,
Heavy
Residential
construc-
tion, Utilities,
Warehouse
Severe to
Commercial
Continuous
construction,
Oil & Gas,
Mining
1) Failure of a worker to perform "before each use" inspection or failure of an inspection by a worker shall initiate the requirement for inspection by a
competent person.
2) Failure of a competent person to perform inspections as specified in this Table, or failure of an inspection by the competent person shall initiate product
revalidation or disposal.
3) Determination of the type of use category shall be determined by a competent person.
4) A SRL that is considered non-repairable, or not designed for disassembly such that internal inspection is not possible without rendering it unserviceable, is
not subject to revalidation inspection. These SRL's shall have service life and other inspection requirements as provided by the manufacturer's instructions.
Conditions of Use
Good storage conditions,
indoor or infrequent outdoor
use, room temperature,
clean environments
Fair storage conditions, in-
door and extended outdoor
use, all temperatures, clean
or dusty environments
Harsh storage conditions,
prolonged or continuous
outdoor use, all tempera-
tures, dirty environment
15
Competent
Worker
Person
Inspection
Inspection
Frequency
Frequency
Before each
Annually
use
Before each
Semi-annually
use
to annually
Before each
Quarterly to
use
semi-annually
APPLIES TO CSA
ONLY Product
Revalidation
Frequency
At least every
5 years but not
more than inter-
vals required by
the manufacturer
At least every
2 years but not
more than inter-
vals required by
the manufacturer
At least annually
but not more than
intervals required
by the manufac-
turer