Descargar Imprimir esta página

AEG KMK761080B Manual De Instrucciones página 59

Ocultar thumbs Ver también para KMK761080B:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 246
2. SAFETY INSTRUCTIONS
2.1 Installation
WARNING!
Only a qualified person must install this
appliance.
• Remove all the packaging.
• Do not install or use a damaged
appliance.
• Follow the installation instructions supplied
with the appliance.
• Always take care when moving the
appliance as it is heavy. Always use safety
gloves and enclosed footwear.
• Do not pull the appliance by the handle.
• Install the appliance in a safe and suitable
place that meets installation requirements.
• Keep the minimum distance from other
appliances and units.
• Before mounting the appliance, check if
the appliance door opens without restraint.
• The appliance is equipped with an electric
cooling system. It must be operated with
the electric power supply.
• The built-in unit must meet the stability
requirements of DIN 68930.
Cabinet minimum height
(Cabinet under the worktop
minimum height)
Cabinet width
Cabinet depth
Height of the front of the
appliance
Height of the back of the
appliance
Width of the front of the ap‐
pliance
Width of the back of the ap‐
pliance
Depth of the appliance
Built in depth of the appli‐
ance
Depth with open door
2.2 Electrical connection
• All electrical connections should be made
• The appliance must be earthed.
• Make sure that the parameters on the
• Always use a correctly installed
• Do not use multi-plug adapters and
• Make sure not to cause damage to the
444 (460) mm
560 mm
• Do not let mains cables touch or come
550 (550) mm
455 mm
• The shock protection of live and insulated
440 mm
• Connect the mains plug to the mains
595 mm
559 mm
• If the mains socket is loose, do not
567 mm
• Do not pull the mains cable to disconnect
546 mm
• Use only correct isolation devices: line
882 mm
Ventilation opening mini‐
mum size. Opening placed
on the bottom rear side
Mains supply cable length.
Cable is placed in the right
corner of the back side
Mounting screws
WARNING!
Risk of fire and electric shock.
by a qualified electrician.
rating plate are compatible with the
electrical ratings of the mains power
supply.
shockproof socket.
extension cables.
mains plug and to the mains cable. Should
the mains cable need to be replaced, this
must be carried out by our Authorised
Service Centre.
near the appliance door or the niche below
the appliance, especially when it operates
or the door is hot.
parts must be fastened in such a way that
it cannot be removed without tools.
socket only at the end of the installation.
Make sure that there is access to the
mains plug after the installation.
connect the mains plug.
the appliance. Always pull the mains plug.
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
560x20 mm
1500 mm
3.5x25 mm
ENGLISH
59

Publicidad

loading

Este manual también es adecuado para:

Kmk761080mKmk761080t