EN
SERVICE MENU
7 0
Boiler temp. Setting - Glasses
Warning: Incorrect parameter setting will cause poor rinse quality or cause an excessive amount of steam.
SERVICE MENU
8 2
Boiler temp. Setting - Plates
Warning: Incorrect parameter setting will cause poor rinse quality or cause an excessive amount of steam.
SERVICE MENU
6 0
Set.wash temp.
Warning: Incorrect parameter setting will cause poor wash quality or cause an excessive amount of steam.
SERVICE MENU
0 5
Detergent dosing
1: 0,7 ml/l
2: 0,9 ml/l
3: 1,1 ml /l
4: 1,3 ml /l
5: 1,5 ml /l
6: 1,7 ml /l
7: 1,9 ml /l
8: 2,1 ml /l
9: 2,3 ml /l
10: 2,5 ml/l
page 38
3.4 Glasses-cycles rinse temperature setting
Use keys
B
setting -
Glasses. Confi rm the selection by pressing the key
Use keys
B
°C
the selection of every digit by pressing key
This parameter allows adjusting the boiler rinse water temperature exclusively used
during the glasses cycles P1,
3.5 Plates and Clean cycles rinse temperature setting
Use keys
B
setting -
Plates. Confi rm the selection by pressing the key
Use keys
B
°C
the selection of every digit by pressing key
This parameter allows adjusting the boiler rinse water temperature exclusively used
during the Plates and Clean cycles P4,
3.6 Wash temperature setting
Use keys
B
Confi rm the selection by pressing the key
Use keys
B
°C
the selection of every digit by pressing key
This parameter allows adjusting the wash tank water- temperature used in all cycles
except in the
3.7 Detergent dosing setting
Use keys
B
Confi rm the selection by pressing the key
Use keys
B
selection by pressing key
This parameter allows adjusting the detergent amount injected in the wash tank
used in all cycles.
The selectable values go from 1 to 10 and they correspond, approximately to the
following dosings (referred to the o.e.m. detergent dosing pump):
(increase) and
C
(decrease) to select the parameter
(increase) and
C
(decrease) to select the desired value (°C). Confi rm
P2
and P3.
(increase) and
C
(decrease) to select the parameter
(increase) and
C
(decrease) to select the desired value (°C). Confi rm
(increase) and
C
(decrease) to select the parameter
(increase) and
C
(decrease) to select the desired value (°C). Confi rm
P0
one.
(increase) and
C
(decrease) to select the parameter
(increase) and
C
(decrease) to select the desired value. Confi rm the
Start
F.
Start
Start F
and move to the following fi eld.
Start
Start F
and move to the following fi eld.
P5, P6
and P7.
Start
F.
Start F
and move to the following fi eld.
Detergent
Start
F.
Boiler temp.
F.
Boiler temp.
F.
Set. wash temp.
dosing.