• Diameter (inches) of range connection opening
- Power cord: 1 3/8"
- Conduit: 1 1/8"
Case 4
• Voltage: 120/208 volts (3-wire)
• Range rating: 12,501 W - 18,500 W
• Specified rating of power supply-cord kit,
amperes: 50 A
• Diameter (inches) of range connection opening
- Power cord: 1 3/4"
- Conduit: 1 3/8"
3, 4 - Wire Electrical Wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
Connecting the Power Cord /
Conduit
The rear access cover
must be removed. Loosen
a
the two screws with a screwdriver. The terminal
block will then be accessible.
Use the cord/conduit connection plate
the power cord or conduit. Leave the connection
plate as installed for power cord installations.
Remove the connection plate for conduit
installations and rotate it to use the smaller 1 1/8
in. (2.8 cm) conduit hole
c
(3.5 cm) power cord hole
1
/
" (2.8 cm)
1
8
1
3
/
" (3.5 cm)
8
For power cord
installations, hook the strain
e
relief over the 1 3/8 in. (3.5 cm) power cord hole
to install
b
instead of the 1 3/8 in.
.
d
located below the rear of the oven. Insert the
power cord through the strain relief and tighten it.
For conduit installations, insert the conduit strain
relief in the 1 1/8 in. (2.8 cm) conduit hole. Then
install the conduit through the body of the strain
relief and fasten the strain relief with its ring.
Ring
f
Body
g
Cord/Conduit Connection Plate
h
Conduit
i
3-Wire Connection: Power Cord
WARNING
• The white middle (neutral or ground) wire of a 3-
wire power cord or a 3-wire conduit has to be
connected to the middle post of the main
terminal block. The remaining two wires of the
power cord or conduit have to be connected to
the outside posts of the main terminal
connection block. Failure to do so can result in
electrical shock, severe personal injury or death.
• If screws are not tightened securely, it can result
in electrical spark and severe personal injury or
death.
1
For power cord installations, hook the strain
relief over the power cord hole (1 3/8") located
below the rear of the oven.
INSTALLATION