Lock Dimensions - Swingbolt
Bolt Switch Operating Instructions
The bolt switch is used to monitor the position of the bolt. Depending on the wiring harness color code, the
connections are as follows:
COM: Blue
OR
N/O:
Red
N/C:
Green
With the bolt extended in the locked position, the closed circuit
connection is between COM and N/C. With the bolt retracted
in the unlocked position, the closed circuit connection is between
COM and N/O.
Switch Specifications:
Rated Voltage:
Operating Speed:
CAUTION:
The bolt switch was not intended for high voltage applications
Never carry or support the weight of the lock with the wires.
This can damage the bolt switch
COM: White with the letter designator C
N/O:
Blue
N/C:
White
125 VAC (3 Amps), 30 VDC (2 Amps)
1 to 500 mm/second (0.04 to 19.7 in./second)
dormakaba USA Inc. | Safe Lock Installation Guide 7034.1121 Rev C 07/22
Figure 6
Bolt extended (locked)
Bolt retracted (unlocked)
Figure 7