Troubleshooting
Códigos de error en modelos de velocidad constante
Cuando el aire acondicionado falla, el receptor de temporización de la placa controladora, la luz de
avería de la placa PCB de la unidad exterior y el panel LCD del control remoto mostrarán el código de
avería correspondiente de acuerdo con las diferentes indicaciones de avería.
La respuesta específica es la siguiente:
ERROR
DESCRIP-
CODE
TION
E0
Blink 11 times, stop 2
seconds
E1
Blink 1 time, stop 2
seconds
E2
Blink 2 times, stop 2
seconds
E3
Blink 3 times, stop 2
seconds
E4
Blink 4 times, stop 2
seconds
E5
Blink 5 times, stop 2
seconds
E6
Blink 6 times, stop 2
seconds
E7
Blink 7 times, stop 2
seconds
E8
Blink 8 times, stop 2
seconds
E9
Blink 9 times, stop 2
seconds
EA
Blink 10 times, stop
2 seconds
F1
Blink 5 times, stop 2
seconds
F2
Blink 2 times, stop 2
seconds
F3
Blink 3 times, stop 2
seconds
F4
Blink 4 times, stop 2
seconds
F5
Blink 5 times, stop 2
seconds
F6
Flashing 6 times,
stop 2 seconds
POSSIBLE CAUSE
Refrigerant leakage
TA (indoor unit temperature
sensor) is abnormal
TWD (defrosting sensor sensor)
is abnormal
TE(indoor unit coil sensor) is
abnormal
Drainage system failure
Communication failure
Outdoor protection (phase
sequence)
TL(outdoor condensing tempe-
rature sensor) is abnormal
TP(Discharge temperature sen-
sor) is abnormal
Low pressure protection.
Outdoor protection (Discharge
temperature is too high.)
Communication failure between
indoor unit and outdoor unit.
Exhaust overtemperature pro-
tection.
Outdoor fan 1 # is abnormal
Indoor fan is abnormal
Outdoor temperature sensor
Compressor over-current pro-
tection
138
POSIBLE CAUSA
•
Internal compressor protection
•
System less refrigerant
•
Reverse failure of the 4-way valve
•
Sensor damage
•
Bad sensor contact
•
Sensor damage
•
Bad sensor contact
•
Sensor damage
•
Bad sensor contact
•
Water pump failure
•
Deterioration of differential switch
•
Float switch blocked
•
Communication line sequential error
•
Bad contact of the communication line
•
Power line is out of phase
•
Power line phase sequence error
•
Sensor damage
•
Bad sensor contact
•
Sensor damage
•
Bad sensor contact
•
System with less refrigerant
•
Action of the external protective device
•
Communication line sequence error
•
Communication line bad contact
•
Switching failure of the external fan
•
Bad connection of the fan connection
•
Motor damage
•
Bad connection of the fan connection
•
Motor damage
•
Sensor damage
•
Bad sensor contact
•
Compressor clogging
•
Low voltage
English