11. AUTOMATIC MEMORY ACCUMULATION
Selection of manual/automatic accumulation function (Selection of manual / automatic print function). Selection of animal scale, peak value
retain and counting function.
STEP
OPERATION
Press
1
Press
2
Press
3
Press
Press
4
Press
Press
5
* Note: (a) sampling: when net weight on scale is zero (tare can be removed by pressing tare key if net weight is not zero), the sample,
wich must be <200 pieces, i.e. between 1 to 199, is put on the scale. Press
is displayed. Press
Press
, confirm the completion of sampling. Weighing status is redisplayed. Sampling is memorized even with power off.
32
DISPLAYING
n 12
AUt 0
AUt 0
AUt 0
AUt 1
AUt 2
AUt 3
0
and
to enter the desired value.
USER'S MANUAL BR80-BR90
CONTENIDOS
To display times of accumulation.
The selection of manual/automatic accumulation AUt = 0, manual accu-
mulation
AUt = 1, automatic accumulation and print when weight is added,
indicator is lit.
AUt=2, automatic memorize displayed value when weight is added. Accu-
mulate and print final stable values after load down to below 20 d.
indicator is lit.
AUt=3,dynamic weighing method. At weighing >20d: the buzzer sounds
"du" and lock is displayed for 6 seconds. Then lock is released for weighing
<20d; automatic accumulation and print. Suggest Flt>30.
cator is list.
AUt=4, peak value fixed weighing method. At
weighing>20d, the buzzer sounds "du" and lock is displayed. When
weighing <20d, fixed data displays with flash, automatic accumulation and
print. Lock can be released by pressing any key.
AUt=5,dynamic weighing method. Manual accumulation and print.
AUt=6, peak value fixed weighing method. Manual accumulation and print.
AUt=7, counting function. *note
Digits displays with flash.
Sets F·S
Move binking digit to the right bit.
e.g. AUt=3 expresses dynamic weighing method.
Return to normal weighing status.
, input quantity of the sample (e.g.30), Cnt030