USER'S MANUAL. PROMAX-10
Accuracy
Analogue channels
Digital channels
DIGITAL SIGNALS MEASUREMENT
MER (Modulation error ratio)
Measurement range
Accuracy
BER (Bit error rate)
Measured before RS decoding
Measurement range
Constellation Diagram
Lock range
Symbol rate
Measurement range
Datalogger
Modulation type
Bandwidth
Frequency tuner
VIDEO / AUDIO RATIO MEASUREMENT (ANALOGUE CHANNELS)
Measurement
Measurement range
Audio subcarrier frequency
Variable
Accuracy
CARRIER / NOISE RATIO MEASUREMENT
Measurement
Analogue channels
Digital channels
(5)
Measurement range
Analogue channels
Digital channels
Accuracy
04/2004
± 2 dB (from 0 to 40 °C) for negative video
(3)
modulation
.
± 3 dB (from 0 to 40 °C) for 8 MHz bandwidth
channels.
22 dB to 34 dB for 64 QAM.
± 2 dB
10 E-2 to 10 E-8
DVB-QAM signals (Annex A/B/C) and DOCSIS /
Euro-DOCSIS
-10 dBmV to 60 dBmV
1000 to 7000 Msym/s for 16/64/256 QAM
For each digital channel, the level and the MER can
be stored.
(BER for data dumping to printer or transfer to PC)
16/32/64/128/256 QAM ITU J1 annex A/C and
64/256 QAM ITU J1 annex B.
6/8 MHz (switchable)
62.5 kHz.
Ratio of video to audio carrier levels.
From 0 to 40 dB
4-9 MHz.
± 2 dB (from 0 to 40 ºC) for FM audio carrier
Ratio between carrier level and the channel's noise
level.
Ratio between the channel power and the noise
level. The frequency where noise is measured is
user definable in absolute or relative value. In the
relative mode, the unit takes as default frequency
offset the value BW/2 + 0.5 MHz.
40-50 dB for input level between 60 and 70 dBµV.
> 50 dB for input level > 70 dBµV.
> 30 dB for input level > 60 dBµV.
± 2 dB (45 – 862 MHz) ± 3 dB (5 – 45 MHz)
(4)
.