g)
BEEP
This function permits to activate (ON) or deactivate (OFF) the PROMAX-10
beeper. When it is on, it sounds on pressing any key or when turning the rotary
selector in order to alert the user.
h)
LANGUAGE
This field permits to select the language between: ESPANOL, FRANÇAIS,
ENGLISH and DEUTSCH.
i)
EXTERNAL UNITS POWER SUPPLY (VLNB)
By means of the PROMAX-10 it is possible to provide the voltage necessary to
feed external units (MMDS antennas Multichannel Multipoint Distribution Service
in case of terrestrial television without cable wireless cable) by the signal input
connector.
This voltage will have to be provided externally by the power input [4] and to be
included in the margin from 21 to 25 V, in opposite case the instrument will not allow to
activate this function, displaying the message "Error VEXT " at the moment of the
configuration.
The activation or deactivation of VLNB takes place according to the described
process next:
-
Press repeatedly the key CONFIG until acceding to the second screen of the
configuration menu.
-
Turn the rotary selector until appears shaded line VLNB.
-
Press the rotary selector to activate the selection. Turning the rotary selector, this
one goes successively of OFF to ON.
-
Finally, to press the rotary selector to activate the configuration changes.
When surpassing the maximum LNB current consumption the output feeding
will be deactivated and LED (V
reactivate again the LNB voltage, after solving the cause of malfuction, it must be
access again to the instrument configuration according to the sequence previously
described.
Before using the LNB feeding function make sure of absence of other power
supplies in the measurement/power supply connector like DC / AC voltages.
The entrance of external voltages when trying to feed from the PROMAX-10, can
produce damages in the implied equipment.
To leave the global configuration menu, just press the key of the operating mode
you wish to accede.
The lower line of the screen shows the version of the unit control software
(2.32 in previous figure)