MIDI Data Format/MIDI-Datenformat/Format de données MIDI/Formato de datos MIDI
(3-6-1-2) TEMPO CONTROL
binary
hexadecimal
11110000
F0
01000011
43
01111110
7E
00000000
01
0ttttttt
TT
0ttttttt
TT
0ttttttt
TT
0ttttttt
TT
11110111
F7
The internal clock will be set to the received Tempo value.
Tempo Meta Event is a large data block (24-bit),it is divided into 4 groups with 7-bits going
into each of the Tempos 1-4 (4 receives the remaining 3 bits).
(3-6-2) UNIVERSAL SYSTEM EXCLUSIVE
(3-6-2-1) UNIVERSAL REALTIME MESSAGE
(3-6-2-1-1) MIDI MASTER VOLUME (Receive only)
binary
hexadecimal
11110000
F0
01111111
7F
01111111
7F
00000100
04
00000001
01
0sssssss
SS
0ttttttt
TT
11110111
F7
or
11110000
F0
01111111
7F
0xxxnnnn
XN
00000100
04
00000001
01
0sssssss
SS
0ttttttt
TT
11110111
F7
The volume for all channels will be changed simultaneously.
The TT value is used as the MIDI Master Volume value. (the ss value is ignored.)
(3-6-2-2) UNIVERSAL NON REALTIME MESSAGE
(3-6-2-2-1) GENERAL MIDI SYSTEM ON
binary
hexadecimal
11110000
F0
01111110
7E
01111111
7F
00001001
09
00000001
01
11110111
F7
or
11110000
F0
01111110
7E
0xxxnnnn
XN
00001001
09
00000001
01
11110111
F7
Depending upon the received ON message, the System Mode will be changed to XG.
Except MIDI Master Tuning, all control data be reset to default values.
This message requires approximately 50ms to execute, so sufficient time should be allowed
before the next message is sent.
The bank select message for the channel 10 and the NRPN message are not received in the GM
mode.
(3-6-3) XG STANDARD
(3-6-3-1) XG PARAMETER CHANGE
(3-6-3-1-1) XG SYSTEM ON
binary
hexadecimal
11110000
F0
01000011
43
0001nnnn
1N
01001100
4C
00000000
00
00000000
00
01111110
7E
00000000
00
11110111
F7
Depending upon the received ON message, the SYSTEM MODE will be changed to
XG.Controllers will be reset, all values of Multi Part and Effect, and All System values denoted
by "XG" data within All System will be reset to default values in the table.
This message requires approximately 50ms to execute, so sufficient time should be allowed
before the next message is sent.
(3-6-3-1-2) XG PARMETER CHANGE
binary
hexadecimal
11110000
F0
01000011
43
0001nnnn
1N
01001100
4C
0aaaaaaa
AA
0aaaaaaa
AA
0aaaaaaa
AA
0ddddddd
DD
|
|
11110111
F7
170
Exclusive status
YAMAHA ID
Style
Tempo4
Tempo3
Tempo2
Tempo1
End of Exclusive
Exclusive status
Universal Realtime
ID of target Device
Sub-ID #1=Device Control Message
Sub-ID #2=Master Volume
Volume LSB
Volume MSB
End of Exclusive
Exclusive status
Universal Realtime
When N is received N=0-F,
whichever is received.
When N is transmitted N always=0.
X = don't care
Sub-ID #1=Device Control Message
Sub-ID #2=Master Volume
Volume LSB
Volume MSB
End of Exclusive
Exclusive status
Universal Non-Realtime
ID of target Device
Sub-ID #1=General MIDI Message
Sub-ID #2=General MIDI On
End of Exclusive
Exclusive status
Universal Non-Realtime
When N is received N=0-F, whichever is received.
When N is transmitted N always=0.
X = don't care
Sub-ID #1=General MIDI Message
Sub-ID #2=General MIDI On
End of Exclusive
Exclusive status
YAMAHA ID
Device Number
Model ID
Address High
Address Mid
Address Low
Data
End of Exclusive
Exclusive status
YAMAHA ID
Device Number
Model ID
Address High
Address Mid
Address Low
Data
End of Exclusive
For parameters with data size of 2 or 4, transmit the appropriate number of data bytes.
For more information on Address and Parameters, refer to < Table 1-2 > - < Table 1-8 >.
The data types listed below are transmitted and received.
System Data
Multi Effect1 Data
Multi EQ Data (PSR-740 ONLY)
Multi Effect2 Data (PSR-740 ONLY)
Special Effect Data (PSR-740 ONLY)
Multi Part Data
A/D Part Data (PSR-740 ONLY)
Drums Setup Data
(3-6-3-2) XG BULK DUMP
binary
hexadecimal
01110000
F0
Exclusive status
01000011
43
YAMAHA ID
0000nnnn
0N
Device Number
01001100
4C
Model ID
0bbbbbbb
BB
ByteCount MSB
0bbbbbbb
BB
ByteCount LSB
0aaaaaaa
AA
Address High
0aaaaaaa
AA
Address Mid
0aaaaaaa
AA
Address Low
0ddddddd
DD
Data
|
|
0ccccccc
CC
Check sum
11110111
F7
End of Exclusive
For more information on Address and Byte Count, refer to < Table 1-2 > - < Table 1-8 >.
The Check Sum value is set such that the sum of Byte Count, Address, Data, and Check Sum
has value zero in its seven least significant bits.
If the top of the block is appointed to the Address the XG Bulk Dump, Bulk Request will be
received.
The Block is a unit that consists of the data, arranged in the list, as the Total Size.
The data types listed below are transmitted and received.(These are transmitted only after a
Bulk Dump request is received.)
System Data
System Information (Transmit ONLY)
Multi Effect1 Data
Multi EQ Data (PSR-740 ONLY)
Multi Effect2 Data (PSR-740 ONLY)
Special Effect Data (PSR-740 ONLY)
Multi Part Data
A/D Part Data (PSR-740 ONLY)
Drums Setup Data
(3-6-3-3) XG PARAMETER REQUEST (Receive only)
binary
hexadecimal
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0011nnnn
3n
Device Number
01001100
4C
Model ID
0aaaaaaa
AA
Address High
0aaaaaaa
AA
Address Mid
0aaaaaaa
AA
Address Low
11110111
F7
End of Exclusive
For more information on Address and Byte Count refer to < Table 1-2 > - < Table1-8 >.
The data types listed below are received.
System Data
Multi Effect1 Data
Multi EQ Data (PSR-740 ONLY)
Multi Effect2 Data (PSR-740 ONLY)
Special Effect Data (PSR-740 ONLY)
Multi Part Data
A/D Part Data (PSR-740 ONLY)
Drums Setup Data
(3-6-3-4) XG DUMP REQUEST (Receive only)
binary
hexadecimal
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
0010nnnn
2n
Device Number
01001100
4C
Model ID
00aaaaaaa
AA
Address High
00aaaaaaa
AA
Address Mid
00aaaaaaa
AA
Address Low
11110111
F7
End of Exclusive
For more information on Address and Byte Count refer to < Table 1-2 > - < Table1-8 >.
The data types listed below are received.
System Data
System Information
Multi Effect1 Data
Multi EQ Data (PSR-740 ONLY)
Multi Effect2 Data (PSR-740 ONLY)
Special Effect Data (PSR-740 ONLY)
Multi Part Data
A/D Part Data (PSR-740 ONLY)
Drums Setup Data