3.5
Information about the app
To obtain more information (if available) about the app, download the app and start it, scan the QR code in
the case.
3.6
Information about the field of applications
Please refer to the Hilti product page for more information about the field of applications.
4
Technical data
4.1
Direct fastening tool
Weight
Tool length
Nail length
Recommended maximum fastening rate
Application temperature (ambient temperature)
Compression stroke
Pressure required
Maximum emitted transmission power
Frequency
4.2
Noise information determined in accordance with EN 15895
The sound pressure and vibration values given in these instructions have been measured in accordance
with a standardized test and may be used to compare one fastening tool with another. They may be used
for a preliminary assessment of exposure. The data given represents the main applications of the fastening
tool. However, if the fastening tool is used for different applications, with different accessories or is poorly
maintained, the data may vary. This may significantly increase exposure over the total working period. An
estimation of the level of exposure should also take into account the periods of time when the tool is not
actually in use. This may significantly reduce exposure over the total working period. Prescribe additional
safety measures to protect the operator from the effects of noise and/or vibration, such as: Maintenance of
the direct fastening tool and its additional equipment or accessories, keeping the operator's hands warm,
organization of work procedures.
The noise values listed were determined under the following conditions:
Noise information conditions
Cartridge
Power setting
Application
Noise information in accordance with EN 15895
Sound (power) level (L
WA
Emission sound pressure level (L
Peak sound pressure emission level (L
4.3
Vibration
The vibration value that must be specified in accordance with 2006/42/EC does not exceed 2,5 m/s².
5
Operation
5.1
Safety devices
Before commencing work, check that all safety devices are fitted and that they are functioning correctly.
All parts must be fitted correctly and fulfill all conditions necessary for the correct operation of the tool.
22
English
Printed: 30.05.2018 | Doc-Nr: PUB / 5433084 / 000 / 00
)
)
pA
)
pCpeak
DX 5
3.37 kg
DX 5
478 mm
DX 5
≤ 72 mm
DX 5
700 rev/h
DX 5
−20 ℃ ... 50 ℃
DX 5
32 mm
DX 5
≥ 174 N
−27.2 dBm
2,400 MHz ... 2,483.5 MHz
6.8/11 caliber, black
2
Fastening 24 mm wood to
concrete (C40) with XU47 P8
105 ±2 dB
101 ±2 dB
133 ±2 dB
2211871