CAUTION
When drilling the wall hole, make
sure to avoid wires, plumbing, and
other sensitive elements.
Outdoor
≈ 12mm /
0.5"
Step 4:
Connect drain hose
The drainpipe is used to drain water
away from the unit. Improper installa-
tion may cause unit and property
damage.
CAUTION
Insulate all piping to prevent conden-
sation, which could lead to water
damage.
If the drainpipe is bent or installed
incorrectly, water may leak and cause
a water-level switch malfunction.
In HEAT mode, the outdoor unit will
discharge water. Ensure that the drain
hose is placed in an appropriate area
to avoid water damage and slippage.
DO NOT pull the drainpipe forcefully.
This could disconnect it.
NOTE ON PURCHASING PIPES
Installation requires a polyethylene
tube (exterior diameter = 2.5cm or
3.7-3.9cm)(depending on models),
which can be obtained at your local
hardware store or dealer.
Wall
Indoor
Indoor Drainpipe Installation
Install the drainpipe as illustrated in the
following Figure.
(A)
Drain hose
Drainpipe
Metal clamp
connecting
port
(B)
Insulation
1-1.5m
(39-59")
Downward slope
1/100
1-1.5m
(39-59")
Downward slope
1/100
1-1.5m
(39-59")
V.3