Technical data sheet
Commercial dishwasher
Legend:
Electrical
1. Voltage (standard version)
connection
plug
plug
Variations in the following countries:
2. Voltage (standard version)
plug
plug
3. Voltage (standard version)
plug
plug
Installation plan PG 8080
Version: 12.12.2012
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Rated load
Fuse rating
Connection cable, min. gauge
Connection cable length (H05(07)RN-F) without
Voltage
Rated load
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Rated load
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Voltage
Rated load
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Rated load
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Voltage
Rated load
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
PG 8080
GB
V/Hz
3N AC 400/50
kW
4.7
A
3 × 10/16
mm²
2.5
m
1.7
V/Hz
AC 230/50
kW
3.1
A
1 x 16
mm²
1.5
m
2.0
V/Hz
AC 230/50
kW
6.7
A
1 x 32
mm²
4
m
2.3
V/Hz
AC 230/50
kW
2.3
A
1 x 13
mm²
1.5
m
2.2
V/Hz
AC 230/50
kW
3,1
A
1 x 15-16
mm²
1.5
m
1.8
V/Hz
AC 230/50
kW
2,3
A
1 x 10
mm²
1.5
m
1.8