Descargar Imprimir esta página

Key Automation TELESCOPIC LEVANTE Serie Instrucciones Y Advertencias Para Su Instalación Y Uso página 44

Actuador para puertas automáticas de corredera

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
BASE internal radar, external radar
AS+
AS-
COM
PHOTO
RADAR (INT/EXT)
Internal radar, external radar compliant with EN 16005
AS+
AS-
COM
PHOTO
RADAR (INT/EXT)
TEST (1/2)
BUS Accessories (NO mechanical selector)
AS+
AS-
Mechanical selector
In entrances with two sliding panels with anti-panic breakout system
(fixed at the sides or to the wall) the automation must be installed
on the outside to allow break-out in any position; photocells must
therefore be installed to ensure a motor STOP in the event of breakout.
If there are semi-fixed side panels next to the sliding panels which
also have breakout function, instead of the STOP photocells it is
sufficient to install two electrical contacts which break the circuit and
2.4 - Mounting surface materials
TABLE OF FASTENERS FOR MOUNTING SURFACE TYPES
Mounting surface materials
Steel
Aluminium
Aluminium
Reinforced concrete
Plasterboard/hollow bricks
Solid wood
2.5 - Assembly equipment
Before proceeding with assembly, be sure to have all the tools and
materials required to be able to install them with maximum safety,
2.6 - Safety distances
The protective measures regarding crushing and impact during the
opening movement can be considered applied to the danger points
if at least one of the following conditions is met, considering that
a) the panel travels parallel to a flat surface at a distance X
≤ 100 mm from it and there is a safety distance Y ≥ 200 mm
between the secondary edge and the parts facing the room
(see figure).
For telescopic doors, the measurement is made with reference
to the panel nearest to the room
44
A
B
Minimum thickness
5mm
6mm
3mm
>120mm in thinnest point
Must be reinforced with 5 mm steel structure
50mm
Max length [m]
30
Max length [m]
30
Max length [m]
30
Max length [m]
5
cut out the sliding panels if the semi-fixed side panels are opened
(which will always occur in breakout of the sliding panels).
N.B. If just one pair of photocells is installed, they must be
mounted 50 cm above the ground. If two pairs of photocells
are installed, they must be mounted 20 and 100 cm above the
ground.
in accordance with the current regulations. The figure shows some
examples of equipment for the installer.
when most of the users are elderly, infirm, disabled and children,
door contact with the user is unacceptable:
Cable type
PVC LiYY 5x0.34mm²
Cable type
PVC LiYY 6x0.34mm²
Cable type
PVC LiYY TP (twisted pairs)
3x2x 0.5mm²
Cable type
PVC LiYY 8x0.34mm²
Screw type
M8
M8
M8 threaded inserts
Plugs Ø 14mm Screw TE M8
M8
Tie-rod screws TE 13mm Ø 8mm
crushing protection

Publicidad

loading