12 - MENU
12.1 - Parameter modification procedure
By pressing ESC for 2 sec (until the beep): parameter modification
is entered.
With ESC the parameters are scrolled, with P1 and P2 they can
be modified.
Function
Default
1.
55
2.
30
3.
8
4.
4
5.
3
6.
4
7.
70
8.
38
9.
16
A.
2
B.
75
C.
0
D.
0
E.
0
F.
0
G.
0
H.
1
J.
16
L.
0
PROGRAM MENÙ
P1
ESC
P5
ESC
MENU
Min
Max
Value
5
65
Opening Speed
5
50
Closing speed
1
15
Opening slowing speed
1
15
Closure slowing speed
0
16
Braked opening
0
16
Braking closure
10
300
Opening approach space
10
300
Closure approach space
1
100
Force on obstacle
1
60
Permanence time (sec)
50
99
Partial opening stroke percentage
0
1
Electric lock type
0
1
Adaptation to the traffic
0
2
If door forced
0
4
If there is no electricity
0
4
If battery depleted
0
1
Motion direction
0
30
Voltage applied to stopped door
0
2
PHOTO monitoring
Pressing OK for 2 seconds (until the beep) stores the current value.
Pressing ESC again for 2 sec (until the beep): the modification is
exited.
OK
P1
P4
P2
OK
AS
P2
Notes
(cm/sec)
(cm/sec)
(cm/sec)
(cm/sec)
(from 50 to 99%)
0 = monostable
1 = bistable
0 = not enabled
1 = present
0 = resists forcing
1 = opens
2 = remains free
0 = continues operation
1 = opens even if in lock
2 = closes and locks
3 = opens only if not in lock
4 = closes but does not lock
0 = continues operation
1 = opens even if in lock
2 = closes and locks
3 = opens only if not in lock
4 = closes but does not lock
0 = right opening
1 = left opening
0 = not monitored
1 = a monitored device
2 = two monitored devices
EN
73