Descargar Imprimir esta página

Holmatro HWC Serie Manual página 36

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 70
EN
-
Connect the couplers and check whether the coupler locks automatically. Check the locking by
pulling the hoses apart with a normal manual effort. The couplers must not slip.
-
Disconnect the couplers by turning the locking ring and pulling it backwards.
High-Flow couplers:
-
Lubricate the end of the coupler with hydraulic oil or inject WD-40.
-
Lubricate the retainer ring by injecting WD-40 underneath the ring.
-
Check the locking by pulling the hoses apart with a normal manual effort. The couplers must not
slip.
-
Disconnect the couplers by turning the retainer ring.
Connect and disconnect the couplers a few times to improve the internal lubrication of the locking
system.
8.4.3
Dust caps
Check the dust caps for damage. Replace damaged dust caps.
Clean the dust caps with running water. Dry the dust cap and treat it with preservative oil.
8.4.4
Hydraulic hoses
Clean the hose with luke warm water and a mild soap solution.
Check the hose for damage and leaks. Replace the hose if it leaks, has kinks, the reinforced cover
is visible or it has blisters or bulges higher than 1 mm. In case of doubt always contact the Holmatro
dealer who can assess the seriousness of the damage.
Replace the hose no later than 10 years after the date of manufacture, regardless of its use and
external appearance. The date of manufacture is part of the test code, the first 4 digits of the test
code specify the date of manufacture of the hose (yymm*****).
8.4.5
Cutter blades
Apply grease to the cutter blade guides (Fig. 12 and Fig. 13).
8.5
Yearly dealer maintenance
We recommend having the equipment inspected, checked, set and tested once a year by a Holmatro
Certified Technician who has the appropriate knowledge and the necessary tools (see also section 1.7).
The Holmatro dealer can organize the yearly maintenance for you on a contract basis.
8.6
Long term storage
Ensure that the equipment is completely depressurized.
Store the equipment in a dry, well-ventilated area. Use additional preservatives on the external steel
parts.
9
Decommissioning/Recycling
At the end of its service life the equipment can be scrapped and recycled.
Make sure that the equipment is put out of order to avoid any use.
Check that the equipment does not contain any pressurized components.
Recycle the various materials used in the equipment such as steel, aluminium, NBR (Nitrile
Butadiene Rubber) and plastic.
Collect all dangerous substances separately and dispose of them in an environmentally responsible
way.
Consult the Holmatro dealer about recycling.
36
916.219.133_003
HWC/HCC

Publicidad

loading