PARAMETERS
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
iE.D.
5
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
Edge test
tE.D.
6
0 = off
1 = on
LP.o.
7
Parcial opening
Time for automatic closure from parcial opening
TP.C.
8
(0=off)
Flashing light output setup
0 = Steady
1 = Flashing
2 = Two-colour LED strip for barrier (MODE 1)
- gate closed steady red
- gate open LEDs off
- during opening flashing green
- during closing flashing red
- stopped not on limit switch flashing red
3 = two-colour LED strip for barrier (MODE 2)
FP.r.
9
- gate closed steady red
- gate open steady green
- during opening flashing green
- during closing flashing red
- stopped not on limit switch flashing red
N.B.: if this parameter is set as 2 or 3, the settings
of parameter IN.D. will be ignored.
If this parameter is set as 2 or 3, the flashing
light and gate open light outputs will be used for
operation with the LED strip
tP.r.
10
Pre-flashing time (0 = off)
Courtesy light setup
0 = On at end of operation for time TCY
FC.Y.
11
1 = On if gate not closed + duration of TCY
2 = On if courtesy light timer (TCY) time not out
tC.Y.
12
Courtesy light on time
Clearance. Allows to stop before the fully open
CL.E.
position: it is useful to avoid mechanical stress
13
during opening.
Hold-to-run
de.a.
0 = off
14
1 = on
0 = deactivated
1 = gate open light ON/OFF
2 = gate open light proportional
- Slow flashing with gate opening
- Quick flashing with gate closing
- Steady light if gate open
- 2 flashes + pause with gate stationary (position
other than closed)
3 = Electric lock
4 = Magnetic electric lock function with output active
when gate/door is closed
IN.D.
15
N.B. interface with an external relay with 24 Vdc
winding. To activate this function, the pre-flash must
be enabled at the recommended value of 1 sec (tP.r.
≠ 0)
5 = LED strip for gate open light (MODE 1)
- steady light when open and closed
- flashing light in all other positions
6 = LED strip for gate open light (MODE 2)
- gate closed steady red
- gate open LEDs off
flashing red in all other positions
Service interval cycle threshold.
se.r.
16
(0 = off)
DESCRIPTION
DEFAULT
MIN MAX
0
0
1
0
0
1
50
10
100
0
0
900
1 *
0
3
0
0
20
0
0
2
0
0
900
0
0
30
0
0
1
0
0
6
10
0
200
EN
UNIT
TYPE
SL/BA/
OH
SL/BA/
OH
%
SL
s
SL
SL/BA/
OH
SL/BA/
s
OH
SL/BA/
OH
SL/BA/
s
OH
%
BA/OH
SL/BA/
OH
SL/BA/
OH
x 1000
SL/BA/
cicli
OH
29