Safety Messages for Wiring
When installing and operating flame-proof electrical equipment,
the relevant national regulations for installation and operation (e.g.,
EN60079-14, IEC Wiring Regulations and NEC/CEC) must be
observed.
•
To avoid electrical shock hazards, do not connect wires when
power is applied. Failure to observe this warning may lead to
serious injury or death.
•
To maintain the flame-proof integrity of the enclosure, DO NOT
damage the strobe lens cover or threads while disassembling or
reassembling unit.
•
Painting and surface finishes, other than those applied by Federal
Signal Corporation, are not permitted.
•
Cable termination should be in accordance with specifications
applying to the application. Federal Signal recommends that all
cables and cores should be fully identified.
•
Ensure that only the correct equipment-certified glands are used
and that the assembly is shrouded and correctly earthed. Gland
entries are M20-1.5 6H with an option for the M25 entry on the
end of the increased safety box models. See Table 3 on page 24
for choosing correct cable entry devices for Equipment in
Potentially Explosive Atmospheres.
•
Because of space limitations, ensure the cable cores within the
unit are not too slack.
•
In all countries, the wiring must comply with all national and local
codes and standards.
•
Ensure that all nuts, bolts, and fixings are secure.
Model G-STR Global Series Strobe Beacon
Installation and Maintenance Instructions