Brass inserts have the potential to store charge when they are not
plugged. Consideration should be taken to prevent these from
becoming a sparking hazard.
The lens guard has the potential to store charge. Consideration
should be taken to prevent this from becoming a sparking hazard.
Maximum flash frequency is 90 FPM.
Failure to follow all safety precautions and instructions may result in
property damage, serious injury, or death.
Certification
Certificate Nos.: ATEX Cert No.: Baseefa15ATEX0154X
Protection:
Standards:
Specific Conditions of Use:
1.
The Modular Visual Strobe has external non-metallic surfaces
which may provided a potential electrostatic charging hazard.
See the manufacturer's instructions for further information.
2.
The Modular Visual Strobe has metallic components in the non-
metallic walls of the enclosure which can store electrical charge
and therefore may provide a potential electrostatic charging
hazard. The metallic brass inserts have a capacitance of 14 pF.
The metallic guard has a capacitance of 18 pF. See the
manufacturer's instructions for further information.
6
All manuals and user guides at all-guides.com
IECEx Cert No.: IECEx BAS 15.0103X
ATEX coding:
Ex db IIC T3 Gb
Ex db e IIC T3 Gb
Ex tb IIIC T200°C Db IP66
(Tamb= -50°C to +70°C)
EN60079-0: 2012 + A11:2013, EN60079-1: 2014
EN60079-7: 2007, EN60079-31:2014,
IEC60079-0: 6
IEC 60079-7: 4
Model G-STR Global Series Strobe Beacon
II 2 G D
Ed., IEC 60079-1 7
th
Ed., IEC60079-31: 2
th
Ed.,
th
Ed.