c.
Connect the earth ground wire to the terminal block pole
marked
120 Vac or 220-240 Vac Ex de Models
a.
See Figure 12 on p. Connect the line (hot) power source wire
to the terminal block pole marked L1/+ .
b. Connect the neutral (common) power source wire to the
terminal block pole marked
c.
Connect the ground wire to the terminal block pole marked
5.
Secure the cover on the terminal box with the four M4 screws.
Ensure that the gasket is properly seated to maintain the IP rating.
Do not overtighten the screws.
6.
Test the beacon for proper operation.
Safety Messages to Maintenance Personnel
Listed below are some important safety instructions and precautions
you should follow:
Read and understand all instructions before operating this system.
If you acquired a significant quantity of units, then it is
recommended that spares are also made available.
Any maintenance to the beacon system must be done with power
turned off.
Any maintenance to the beacon system must be performed by a
trained electrician who is thoroughly familiar with all applicable
national and local codes in the country of use.
Never alter the unit in any manner. Safety of the unit may be
affected if additional openings or other alterations are made to the
internal components or housing.
Repair of flamepaths is not intended.
Model G-STR Global Series Strobe Beacon
Installation and Maintenance Instructions
.
L2/-
.
.
19