4.2.7 Transistor
Range
hFE
Protección de sobrecarga: Fusible (F250mA/250V)
4.2.8 Capacitance
Range
2nF
20nF
200NF
2µF
200µF
Overload protection: Fuse (F250mA/250V)
4.2.9 DC Current
Range
2mA
20mA
200mA
10A
Overload protection: fuse with measuring range of mA (F250mA/250V); fuse
with measuring range of 10A (FF10A/500V).
Maximum input current: mA grade: 200mA DC or AC RMS; 10A grade: 10A
DC or AC RMS.
When measured current is greater than 10A, continuous measurement time
should not be more than 10 seconds. Stop the current being measured
after 15 minutes.
KPS-MT40 • Digital multimeter
Description
hFE approximation on
the display, (0 -1000)
Resolution
1pF
10pF
0,1nF
1nF
100nF
Resolution
1µA
10µA
0,1mA
10mA
36
Test condition
hFE approximation on
the display, (0 -1000)
Accuracy
±(4,0% of reading + 3 digits)
±(6,0% of reading + 10 digits)
Accuracy
±(0,8% of reading + 3 digits)
±(1,5% of reading + 1 digit)
±(2,0% of reading + 5 digits)

Publicidad