MENU → CONTROL
→ Screed drying
→ Change code
→ Language, time, display
→ Language:
→ Date:
→ Time:
→ Display brightness:
→ Dimmed displ. bright-
ness:
→ Daylight saving time:
For outdoor temperature sensors with DCF77 receivers, the Daylight saving time: function is not used. The conversion to sum-
mer/winter time takes place via the DCF77 signal. The change takes place:
–
On the last weekend in March at 02:00 (daylight saving time)
–
On the last weekend in October at 03:00 (standard time)
→ Tariffs
→ Tariff for back-up boiler:
→ Electricity tariff type:
(for heat pump)
The hybrid manager uses the tariffs and the heat demand to calculate the costs for the back-up boiler and the heat pump. The more
cost-effective component is used for the heat generation.
→ Offset
→ Room temperature: K
→ Outdoor temperature: K
→ Factory settings
2.12.4
Installation configuration menu item
MENU → SETTINGS → Installer level → Installation configuration
→ Installation
→ Water pressure: bar
→ eBUS components
→ Adaptive heat curve:
→ Automatic cooling:
→ Outdoor temp., 24 hr av.: °C
10
Activate the Screed drying profile function for freshly laid screed in accordance with the construc-
tion regulations.
The system control regulates the flow temperature independently of the outdoor temperature. Setting
screed drying menu item Installation configuration (→ Chapter 2.12.4)
After the power is switched off, the date is retained for approx. 30 minutes.
After the power is switched off, the time is retained for approx. 30 minutes.
Brightness during active use.
Brightness in standby.
→ Automatic
→ Manual
Enter a gas, oil or electricity tariff
→ Single tariff
→ High tariff:
The costs are always calculated using the high tariff.
→ Dual tariff
→ Dual tariff weekly planner
→ Low tariff:
Dual tariff weekly planner: Up to 12 time periods can be set per day
High tariff:: Applies within the time periods
Low tariff:: Applies outside of the time periods
The costs are calculated using the high and low tariffs.
Comparison of the temperature difference between the measured value in the system control and
the value for a reference thermometer in the living room.
Comparison of the temperature difference between the measured value in the outdoor temperature
sensor and the value for a reference thermometer in the living room.
The system control resets all of the settings to the factory settings and calls up the installation assist-
ant.
Only the competent person can call up the installation assistant.
List of eBUS components and their software versions
Automatic fine adjustment of the heat curve. Prerequisite:
–
The suitable heat curve for the building is set in the Heat curve: function.
–
The correct zone is assigned to the system control or the remote control in the Zone
assignment: function.
–
Expanded is selected in the Room temp. mod.: function.
Factory setting: Deactivated
When a heat pump is connected, the system control automatically switches between heating
mode and cooling mode.
Factory setting: Deactivated
Operating and installation instructions sensoCOMFORT 0020287900_01