2.12.2 INFORMATION menu item
MENU → INFORMATION
→ Current temperatures
→ Zone
→ DHW temperature
→ DHW circuit 1
→ Water pressure: bar
→ Current room air humidity
→ Energy data
→ Solar yield
→ Environmental yield
→ Power consumption
→ Fuel consumption
→ Heat recovery
Display of energy consumption and energy yield
In the display and in the app that can also be used, the control displays values for the energy consumption and/or the energy yield.
The control displays an estimation of the values for the installation. Among other things, the values are influenced by the following:
The installation/design of the heating installation
User behaviour
Seasonal environmental conditions
Tolerances and components
External components, such as external heating pumps or valves, and other consumers and appliances in the household are still not
taken into consideration.
The deviations between the energy consumption or energy yield that is displayed and the actual energy consumption or energy yield
may be significant.
The specifications for the energy consumption or energy yield are not suitable to be used to create or compare energy billing.
The following can be read: Current month, Last month, Current year, Last year, Total
→ Burner status:
→ Air quality sensor 1:
→ Control elements
→ Menu introduction
→ Competent person contact info
→ Serial number
2.12.3 Menu item SETTINGS
MENU → CONTROL
→ Installer level
→ Enter access code
→ Competent person con-
tact info
→ Service date:
→ Fault history
→ Installation configuration
→ Sensor/actuator test
→ Noise reduction mode
0020287900_01 sensoCOMFORT Operating and installation instructions
→ Heating
→ DHW
→ Cooling
→ Installation
→ Heating
→ DHW
→ Installation
Measures the CO
content of the room air
2
Explanation of the control elements
Explanation of the menu structure
Access to the installer level, factory setting: 00
Entering contact details
Enter the next service date for a connected component, e.g. heat generator, heat pump, ventilation
unit
Faults are listed in chronological order
Menu item Installation configuration (→ Chapter 2.12.4)
Selecting a connected functional module and
carrying out a function check of the actuators.
Carry out a plausibility check of the sensors.
Set the time programme in order to reduce the noise level.
9