MENU → SETTINGS → Installer level → Installation configuration
→ Zone assignment:
→ Zone valve status:
→ DHW
→ Cylinder:
→ Target flow temperature: °C
→ Cylinder charging pump:
→ Circulation pump:
→ Anti-legio. day:
→ Anti-legio. time:
→ Cylinder charging hysteresis: K
→ Cylinder charging offset: K
→ Max. cyl. charging time:
→ Cyl. charg. anti-cycl. time: min
→ Parallel cylinder charging:
→ Buffer cylinder
→ Cylinder temp., top: °C
→ Cylinder temp., bottom: °C
→ DHW temp. sensor, top: °C
→ DHW temp. sensor, bottom: °C
→ Heating temp. sensor, top: °C
→ Heating temp. sensor, bottom:
°C
→ Solar cylinder, bottom: °C
→ Max. DHW targ. flow temp.: °C
→ Max. temp. of cylinder 1: °C
0020287900_01 sensoCOMFORT Operating and installation instructions
Assign the system control and/or remote control to the selected zone. The system control
and/or remote control must be installed in the selected zone. The control system also uses
the room temperature sensor for the assigned unit. The remote control uses all of the val-
ues for the assigned zone. The Room temp. mod.: function is ineffective if you have not as-
signed any zones.
If there is an existing domestic hot water cylinder, the Active setting must be selected.
Factory setting: Active
Define the days on which you want the anti-legionella function to run. On these days, the
water temperature is increased to above 60 °C. The circulation pump is activated. The func-
tion ends after 120 minutes at the latest.
If the Absence function is activated, the anti-legionella function is not carried out. As soon
as the Absence function ends, the anti-legionella function is carried out.
Heating installations with heat pumps use the back-up boiler for legionella protection.
Factory setting: Off
Define the time at which you want the anti-legionella function to run.
Factory setting: 04:00
The cylinder charging starts as soon as cylinder temperature < desired temperature - hyster-
esis value.
Factory setting: 5 K
Desired temperature + offset = flow temperature for the domestic hot water cylinder.
Factory setting: 25 K
Setting the maximum time at which the domestic hot water cylinder can be charged without
interruption. If the maximum time or the target temperature is reached, the system control
enables the heating function. The setting Off means that the cylinder charging time is not
restricted.
Factory setting: 60 min
Setting the time period during which the cylinder charging is blocked after the maximum cyl-
inder charging time has elapsed. During the blocked time, the system control enables the
heating function.
Factory setting: 60 min
When charging the domestic hot water cylinder, the mixing circuit is heated in parallel. The
non-mixed heating circuit is always switched off during cylinder charging.
Factory setting: No
Actual temperature in the upper section of the buffer cylinder
Actual temperature in the lower section of the buffer cylinder
Actual temperature in the upper part of the domestic hot water section of the buffer cylinder
Actual temperature in the lower part of the domestic hot water section of the buffer cylinder
Actual temperature in the upper part of the heating section of the buffer cylinder
Actual temperature in the lower part of the heating section of the buffer cylinder
Actual temperature in the lower section of the solar cylinder
Setting the maximum buffer cylinder target flow temperature for the domestic hot water sta-
tion. The set maximum target flow temperature must be lower than the maximum flow tem-
perature for the heat generator.
If the maximum target flow temperature is set too low, the domestic hot water station cannot
reach the target temperature. While the target temperature is not reached, the system con-
trol does not enable the heat generator for heating mode.
You can find the maximum flow temperature in the installation instructions for the heat gen-
erator.
Factory setting:
80 °C
65 °C if basic system diagram 8 is selected
Setting the maximum cylinder temperature. The solar circuit stops the cylinder charging as
soon as the maximum cylinder temperature has been reached.
Factory setting: 75 °C