2.12
Operating and display functions
Note
The functions described in this section are not available for all system configurations.
To call up the menu, press
2.12.1 CONTROL menu item
MENU → CONTROL
→ Zone
→ Heating → Mode:
→ Cooling → Mode:
→ Name of zone
→ Absence
→ Cooling for several days
→ Fixed value control, circuit 1
→ Heating → Mode:
→ DHW
0020287900_01 sensoCOMFORT Operating and installation instructions
twice.
→ Manual
Uninterrupted retention of the desired temperature
→ Time-contr.
Weekly planner: Up to 12 time periods and desired temperatures can be set per day
The competent person sets how the heating installation behaves outside of the time period in the
Set-back mode: function.
In Set-back mode: means:
–
Eco: The heating is switched off outside of the time periods. Frost protection is activated.
–
Normal: The set-back temperature applies outside of the time periods.
Desired temperature: °C: Applies within the time periods
→ Off
Heating is switched off, domestic hot water continues to be available, frost protection is activated
→ Manual
Uninterrupted retention of the desired temperature
→ Time-contr.
Weekly planner: Up to 12 time periods can be set per day; cooling is switched off outside of the
time periods
Desired temperature: °C: Applies within the time periods
Cooling is switched off outside of the time periods
→ Off
Cooling is switched off, domestic hot water remains available
Changing the name Zone , which was set at the factory
→ All: Applies only to any zones within the specified time period
→ Zone: Applies for the selected zone in the specified time period
During this time, heating mode runs at the defined set-back temperature. Domestic hot water mode
and circulation are switched off. Frost protection is activated; existing ventilation runs at the lowest
level.
Factory setting: Set-back temperature: °C 15 °C
Cooling mode is activated in the specified time period, cooling mode and desired temperature are
used from the Cooling function
→ Manual
Uninterrupted retention of the Target flow temp., desired: °C that the competent person set.
→ Time-contr.
Weekly planner: Up to 12 time periods can be set per day
Within the time period, the Target flow temp., desired: °C is used.
Outside of the time periods, the Target flow temp., set-back: °C is used or the heating circuit is
switched off.
At a Target flow temp., set-back: °C = 0 °C, the frost protection can no longer be guaranteed.
The competent person sets both of these temperatures.
→ Off
The heating circuit is switched off.
→ Desired temperature: °C
→ Weekly planner
→ Set-back temperature: °C
→ Desired temperature: °C
→ Weekly planner
→ Desired temperature: °C
→ Weekly planner
7