52
PROGRAMMING MODE - SETUP MODE
20. Top spin speed – final spin time depends on RPM
Top spin speed setup can be used to set the maximum spin RPM.
Enter setup mode.
You will see LqC1
NOTE
• Top spin speed
0 : 1200 rpm
1 : 1000 rpm
2 : 900 rpm
Press the Hot button.
Press the Warm or the Cold button until
in the display.
Press the Start button.
Press the Warm or the Cold button until
in the display.
Press the Start button. Display
Press Warm or Cold button to select course.
: Hot course
: Warm course
: Cold course
: Delicates course
: None (only for Heater model)
Press the Start button.
Display previous top spin speed.
Press Warm(+) or Cold(-) button to select top spin
speed. (Refer to NOTE below for Top spin speed.)
Press the Start button.
The machine sets up the top spin speed, then advances
to the next process automatically.
1. Continue to set up the next mode.
2. Stop the change of setup value and go back to ready
mode.
• Coin type - Turn on/off toggle switch.
• Card type - Pull the service card.
• All types - Push the Hot button three times.
3 : 800 rpm
4 : 700 rpm
5 : 600 rpm
Button
.
6 : 500 rpm
Display
appears