INSTALLATION
2.6
Electrical connection
The appliance is equipped with a power cord and plug
(Y-type connection, the cord can only be replaced by the
manufacturer, the assistance centre or a qualified installer).
If using a socket near the appliance, insert the plug.
Before connecting the conditioner check that:
-
The power supply voltage and frequency values
comply with the data plate of the appliance.
-
The power supply line is provided with a suitable earth
connection and that it is dimensioned for the maximum
absorption of the conditioner (minimum cable section
equal to 1.5 mm
-
Power is only supplied using a suitable socket through
the supplied plug.
The power cord must be replaced only by the technical
assistance service or by authorised personnel.
The appliance must be connected to 230V/50Hz
mains via an omnipolar switch with a contact opening
distance of minimum 3 mm, or using a device
enabling the complete disconnection of the appliance
in overvoltage III category conditions.
It is possible to carry out the electrical connection using
a cable inside of the wall as indicated in the installation
template (recommended for installations in the upper part
of the wall).
Please check that the power supply is provided with
suitable protections against overloads and/or short-circuits
(using a 10 at delay fuse or other equivalent devices is
recommended).
CP presence contact input connection
When the CP contact opens (connected to a free non-live
contact) the appliance is put is stand-by and CP appears
on the display.
Using this contact, it is possible to connect an external
230V/50Hz Electrical power supply terminal board
A
38
).
2
B
This operation must be performed only by the installer
or by authorised personnel in compliance with current
national regulations
It is essential to disconnect the main switch before making
any connection or maintenance operation in order to avoid
any risk of electrocution.
To carry out direct connections and substitute the power
cord using the cable in the wall, proceed as follows:
-
Space the appliance from the wall using a wooden
wedge or a similar object.
-
Disconnect the power cord by unscrewing the 3
screws from the terminal board.
-
Connect the wall cable checking that the power supply
line is provided with a suitable earth connection and
that it is dimensioned for the maximum absorption of
the conditioner (minimum cable section equal to 1.5
mm
).
2
These operations must be carried out with the
appliance already placed on the bracket, therefore
read the following instructions carefully before
completing the connection.
device that inhibits the functioning of the appliance
such as: open window contact, remote on/off, infrared
presence sensor, qualification badge, etc.
CP presence contact
B
A
U
I
S

Publicidad