INSTALLATION
2.9
Touch-screen display key lock
The key lock is activated by keeping the Timer
on the touch-screen display pressed for
seconds.
Any action is prevented by the user.
2.10
Operations tests and anomaly diagnosis
The conditioner can perform a short self-diagnosis cycle
to check the temperatures detected by the 4 probes and
the status of the 3 inlets.
In order to activate the self-diagnosis function, press the
button within 10 seconds from the electric power
supply.
The display will lit all symbols for 2 seconds and then it will
show the 7 information at 2 second intervals.
Display code
E1
E2
E3
E4
E5
E6
E7
Open CP contact
If the presence contact is not closed, the appliance
doesn't start and the CP alarm appears on the display.
Emergency condensation air discharge
Should any anomaly occur in the condensation water
system, the maximum level float blocks the conditioner
and the OF code appears on the display.
During cooling and dehumidification, electronics switches
the compressor off and keeps the water distribution
system active with the battery - together with the fan - to
disperse excess water in the container. If the problem
Operations after installing
Before leaving, collect the packing and clean any dust on
the appliance with a damp cloth. These operations, though
not strictly essential, transmit a sense of professionalism
to the User.
In order to avoid useless calls from the User, before
leaving:
-
explain the contents of the Manual,
40
symbol
t h r e e
Cause
Broken room temperature RT probe
Broken evaporative battery IPT probe
Broken outdoor air temperature OT probe
Broken conditioner battery OPT probe
Broken indoor air fan motor
Broken outdoor air fan
Lack of communication with the display
The stand-by symbol flashes at 1 second intervals.
To deactivate the lock, keep the Timer symbol pressed for
three seconds once again.
Any key on the remote control deactivates the lock!
After 5 cycles, or when any key is pressed either in the
display or on the remote, the self-diagnosis mode will
stop.
If the conditioner blocks because of an alarm (see following
table), please communicate to the assistance centre the
code on the display to facilitate interventions.
persists, please contact the assistance service.
During heating, condensations should drain freely through
the specific pipe. In the event of an alarm, check that
the condensation pipe is not bent or obstructed, thus
preventing the water from flowing out.
-
explain how to clean the filter.
-
clarify when and how to call the Assistance Service.