Descargar Imprimir esta página

Klein Tools VDV500-920 Manual De Instrucciones página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Check the "CONT" Indicator
6. The "NRM" (Normal) Polarity Indicator
"NRM" (Normal) Polarity Indicator
Test Clip
is connected to the POTS (Plain Ol' Telephone Service) in the
is connected to the POTS (Plain Ol' Telephone Service) in the
is connected to the POTS (Plain Ol' Telephone Service) in the
T14 T14
proper orientation. The "REV" (Reverse) Polarity Indicator
if the wires are reversed.
• The "NRM" (Normal) Polarity Indicator
ABN Test Clip detects higher voltage than the red ABN Test Clip.
• The "REV" (Reverse) Polarity Indicator
ABN Test Clip detects higher voltage than the black ABN Test Clip.
• The "NRM" (Normal) Polarity Indicator and "REV" (Reverse) Polarity
Indicator will both illuminate when AC voltage is present.
• When the RJ11 Test Plug is used, the "NRM" (Normal) Polarity Indicator
will illuminate on a correctly wired and powered POTS (Plain Ol'
Telephone Service) phone jack.
NOTE: The POTS (Plain Ol' Telephone Service) color code convention
(black/positive, red/negative) is the opposite of the multimeter color
code convention (red/positive, black/negative).
RJ45 TERMINATED DATA CABLE WIRE MAP TESTING
1. Insert one end of the data cable to be tested into the RJ45 port
Digital Toner-Pro.
2. Insert the opposite end of the cable into the Digital Probe-Pro's RJ45 Port
3. Enter MAPPING mode by pressing the MODE button
Enter MAPPING mode by pressing the MODE button
Indicators
T18 T18
into mapping mode when the toner is set to mapping mode.
4. A wire pin-to-pin map will be displayed on both the Toner and Probe. The
A wire pin-to-pin map will be displayed on both the Toner and Probe. The
Toner's Wire Map Indicators
which pin on the Toner end of the cable is being mapped. Simultaneously,
which pin on the Toner end of the cable is being mapped. Simultaneously,
the Probe's Wire Map Indicators
the Probe end of the cable is connected to the actively indicated pinout on the
Toner end; this enables detection of mis-wired cables and cable faults (for
example, if pin 3 on the Toner end of the cable is connected to pin 6 on the
Probe end of the cable, when the Toner's #3 Wire Map Indicator illuminates,
the Probe's #6 Wire Map Indicator will illuminate).
5. If the cable being mapped is terminated in T568A, T568B, or Straight-
Through wiring, the Probe's Wire Map Indicators will illuminate 1 through 8,
in the order of contact pin termination, in unison with the Toner's Wire Map
in the order of contact pin termination, in unison with the Toner's Wire Map
Indicators
T18 T18
illuminating all effected wires' LEDs on both the toner and probe during the
detection sequence. For an open circuit, the wire's LEDs on both the toner and
probe will not be illuminated during the detection sequence.
6. If the cable being tested is shielded, the Shield Indicator on both the Toner
If the cable being tested is shielded, the Shield Indicator on both the Toner
and Probe
P5 P5
7. The test will be repeated until one or both ends of the cable is/are
disconnected, or until the Toner's mode is cycled out of Mapping mode.
NOTE: The Digital Probe-Pro cannot ID digital/analog tone signals while in
mapping mode.
OPERATING INSTRUCTIONS
illuminate and blink. The Digital Probe-Pro will automatically go
illuminate and blink. The Digital Probe-Pro will automatically go
T18 T18
. A short circuit between wires is indicated by simultaneously
will illuminate at the end of each sequence.
will illuminate at the end of each sequence.
. If illuminated green, testing can proceed.
T4
will illuminate if the red ABN
will illuminate if the red
T2
T2
T3
will slowly blink in order 1 thru 8, to indicate
will slowly blink in order 1 thru 8, to indicate
will illuminate to indicate which pin on
will illuminate to indicate which pin on
P4 P4
will illuminate
will illuminate
T3
will illuminate when the black
will illuminate
w will illuminate when the red
T21 T21 T21
until the Wire Map
until the Wire Map
T8 T8
on the
on the
.
P14 P14 P14
T19 T19
9

Publicidad

loading

Este manual también es adecuado para:

Vdv500-223Vdv500-163