10. Maintenance:
The purpose of the maintenance plan is to ensure that the compressor remains in good
working condition and that it reaches the maximum of its useful life.
DANGER: Turn the engine off before doing any maintenance. If you need to start the
engine for any checking, first ensure that the area is well ventilated. The exhaust gases
contain carbon monoxide, which is poisonous to the user.
NOTE: Apply only GENERGY original parts or, if not available, components of proven
quality.
Maintenance plan:
10.1
Engine oil
10.2
Air filter
10.3
Spark plug
Engine valves*
Combustion chamber *
Fuel tank*
Fuel hose*
Engine exterior cleaning
10.4
Compressor head oil.
10.5
Compressor head air filters.
10.6
Tank drainage.
10.7
Belt tension check.
10.8
Safety valve check.
10.9
Adjusting the original factory
pressure setting*
Guard belts check
Abnormal noise control
Compressor exterior cleaning
NOTE: If you use the compressor in places with a lot of dust or with high
temperatures, does more frequent maintenance.
NOTE: All services marked with an asterisk (*) should be performed by GENERGY
Technical Service or a GENERGY Authorized Service. You must save the report of the
work done by the workshop.
NOTE: The failure of compliance with the maintenance plan will shorten the life of
the compressor and will increase the possibilities of malfunctions or damages. The
warranty will not be applied in these cases. If one or more services planned were not
done, the warranty will not be applied, unless authorized by the GENERGY Technical
Service or a GENERGY Authorized Service.
ENGINE MAINTENANCE
Check the oil level before each use. After 20 hours, the first oil
change should be made. Every 100 hours of use, do new oil
changes.
Check and clean every 50 hours. At a maximum of 250 hours or
earlier if it is damaged, replace.
Clean and adjust the electrode every 50 hours. At a maximum of
250 hours or earlier if it is damaged, replace.
Adjust every 500 hours*
Clean every 500 hours*
Clean every 500 hours*
Replace every 2 years or earlier if it is damaged*.
Weekly
COMPRESSOR HEAD MAINTENANCE
Check the oil level before each use. Every 200 hours, replace it.
Check and clean every 50 hours. At a maximum of 250 hours or
earlier if it is damaged, replace.
Before each use and after each use.
Monthly or every 100 hours.
Weekly or every 25 hours.
Only in case of failure, malfunction or setting to a different pressure
permanently (MAX 10BAR). This task will always be performed
by a qualified service.
Before each use.
Daily
Weekly
57