4. The sensor channel number will be displayed on the sensor's screen above the temperature/humidity reading. Data
from the sensor will be loaded into the station within 5 minutes. Repeat the whole process if the sensor's signal is
not detected.
Displaying Data from Multiple Sensors, Automatic Cycling through Values from Connected Sensors
Press the
button repeatedly to display data from all connected sensors on the weather station, one by one.
You can also activate automatic cycling through data from all connected sensors:
1. Turning on cycling
Long-press the
button.
Data from all connected sensors will be shown automatically and repeatedly on the station's screen one after another.
2. Turning off cycling
Short press the
button; data cycling will be deactivated.
Radio-Controlled Clock (DCF77)
After registering the wireless sensor, the weather station will automatically search for DCF77 signal (hereinafter referred
to as DCF) for 6 minutes; the
No other data on the screen will be updated and all buttons except for SNOOZE/LIGHT will be disabled during the search.
Holding the RCC button for 3 seconds cancels the search for DCF signal.
Signal detected - the icon stops flashing and the current time and date will be displayed with the
Signal not detected – the
Press the RCC button to repeat the search for DCF signal for 6 minutes.
DCF signal will be synchronised regularly every day between 01:00 and 05:00.
During summertime, the
In normal conditions (at a safe distance from sources of interference, such as television sets or computer monitors) the
detection of time signal takes several minutes.
If the weather station does not detect the signal, follow these steps:
1. Move the weather station to another location and try to detect the DCF signal again.
2. Check the distance of the clock from sources of interference (computer monitors or television sets). The distance
should be at least 1.5 to 2 m during the reception of signal.
3. When receiving DCF signal, do not put the weather station in the proximity of metal doors, window frames another
metal structures or objects (washing machines, dryers, refrigerators etc.).
4. 4. DCF signal reception is weaker in reinforced concrete structures (cellars, high-rise buildings etc.), depending on the
conditions. In extreme cases, place the weather station close to a window in the direction of a transmitter.
The reception of the DCF radio signal is affected by the following factors:
• Thick walls and insulation, basements, and cellars.
• Inadequate local geographical conditions (these are difficult to assess in advance).
• Atmospheric disturbances, thunderstorms, electrical appliances with no interference elimination, television sets and
computers located near the DCF receiver.
If the weather station cannot detect the DCF signal, time and date must be set manually.
Note: If the weather station detects DCF signal but the current time on the display is incorrect (e.g. shifted ±1 hour), you
must always set the correct time zone for the country where you are using the station, see Setting Time Manually. The
current time will be shown with the appropriate time zone difference.
Setting Time Manually
1. Long press the
button.
2. Use the
/
hours – minutes – seconds – time zone.
Confirm each set value by pressing
If no button is pressed within 1 minute, the unit will go back to the main screen.
Setting °C/°F Temperature Unit
Use the slider on the back of the station to choose between °C/°F unit of temperature.
Screen Illumination
Press SNOOZE/LIGHT to briefly activate screen illumination for 5 seconds.
Setting an Alarm
Long-press the
button; AL will appear on the screen and the time setting will start flashing.
Use
/
to set the hours and minutes for the alarm; holding the buttons speeds up adjustment.
Confirm set values by pressing
Pressing
activates (
Snooze Function
You can postpone an active alarm by 5 minutes by pressing the SNOOZE/LIGHT button on the back of the station.
Press the SNOOZE/LIGHT button when the alarm starts ringing. The
To cancel SNOOZE mode, press the
The alarm will trigger again the next day.
If you do not press any button while the alarm is ringing, the ringing will stop automatically after 2 minutes.
icon will flash depending on the strength of DCF signal.
icon is not displayed.
icon will be displayed below the time value.
buttons (hold to adjust faster) to set the following parameters: 12/24 h time format –
.
.
appears) or deactivates (
button – the
disappears) the alarm.
icon will start flashing.
icon will stop flashing and will remain on the screen.
4
icon.