How The Air Conditioner Works; Dehumidifying Operation - Qlima S5025 Instrucciones De Uso

Ocultar thumbs Ver también para S5025:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
H

HOW THE AIR CONDITIONER WORKS

Press Sleep button
1
Set
Tempe-
1
rature
1 hour
1 hour
COOLING
Press Sleep button
Set
1
Tempe-
rature
1 hour
1 hour
HEATING
Cooling Fan only Cooling Fan only Cooling
Room
tempe-
rature
Time
Set temperature
DEHUMIDIFYING

DEHUMIDIFYING OPERATION

The dehumidifying mode will automatically select the dehumidifying operation based on the difference
between the set temperature and the actual room temperature.
The temperature is regulated while dehumidifying by repeatingly turning on and off of the cooling
operation or fan only. The fan speed is controlled automatically.
In normal cooling operation the air conditioner will also dehumidify the air.
G
NOTE
When the air conditioner is dehumidifying it is likely that the room temperature will decrease.
It is therefore normal that a hygrostat will measure a higher relative humidity. The absolute
humidity in the room will however be lowered, depending on the amount of moisture produced
in the room (cooking, people etc).
4
88
AUTOMATIC OPERATION
When you set the air conditioner in AUTO mode (button 2 on the remote
controller), it will automatically select COOLING, HEATING or FAN only
operation depending on what temperature you have selected and the room
temperature.
The air conditioner will control room temperature automatically round the
1
temperature point set by you.
If the AUTO mode is uncomfortable, you can select desired conditions man-
ually.
SLEEP/ECONOMIC OPERATION
When you push SLEEP button  during COOLING, HEATING or AUTO oper-
ation, the air conditioner will automatically increase (cooling) or decrease
(heating) 1ºC per hour. The set temperature will be steady 2 hours later and
remains steady for 5 hours. After 5 hours the unit will stop. The fan speed
will be automatically controlled.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S5032S5048Sc5025Sc5032Sc5048Sc4125 ... Mostrar todo

Tabla de contenido