INSTALLATION:
WARNING:
Electrical installation should only be carried out by certified electricians.
Always ensure the power cable cannot touch the back of the heater and that it cannot protrude into the
heated area of the heater. The supply cable can be routed safely away from the rear of the heater by fixing
it to the metal brackets using zip ties.
Wiring to this appliance must be connected in accordance with the relevant national electrical safety
standards. It is a Class 1 appliance and must be earthed.
When placed in public areas, installation must comply with relevant local electrical standards. For certain
public buildings like schools and care homes the heaters must be installed according to the specific
legislation for these types of buildings.
The electrical supply to the unit should be provided by connecting to a circuit protected by a fuse or residual
current device (RCD) or Ground Fault circuit interrupter (GFCI ) suitable for the electrical rating of the
appliance. Temperature control must be effected by a Thermostat.
Colour coding used in the supplied mains cable: BROWN wire is to be connected to LIVE ('L'), the BLUE wire
to NEUTRAL ('N') and the GREEN/YELLOW wire to EARTH ('E').
CAUTION:
Ensure mains power is OFF before commencing an installation involving fixed wiring.
Any fixed wiring outside the heater coming into contact or close proximity to the heater must be
protected by sleeving with a temperature rating of at least 90°c.
All cabling behind the appliance must take the shortest route to the edge of the heater.
If installing the heater at an angle (on a sloping roof for example), the supply cable must be at the
lowest end of the heater.
DO NOT
leave the power cable coiled in operation. Shorten the power cable if possible and do not
place excess cable on the rear of the heater.
DO NOT
make Electrical connections behind the heater in either wall or ceiling-mounted positions.
The heater is not to be located immediately below a socket outlet in either wall or ceiling-mounted
positions.
DO NOT
drill through any part of the heater. This will cause irreparable damage and is dangerous.
DO NOT
connect a heater that is damaged in any manner to the power network.
Install the Krystal heater using the supplied mounting hardware only and install in accordance with the
installation guide. Herschel Infrared Ltd cannot accept responsibility for damage, loss or injury caused by,
or resulting from incorrectly installed heaters. Herschel Infrared Ltd will not assume liability for
consequential loss however caused.