Descargar Imprimir esta página

elero Junior 1 Instrucciones De Montaje página 57

Ocultar thumbs Ver también para Junior 1:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Installation
4.4.1
Permissible adjusting range of limit switches
CAUTION
Risk of damage to unit by exceeding permissible range of adjustment.
• T he "retracted" and "ejected" limit switches must not be adjusted any more
than 10 mm in the direction of stroke reduction.
Fig. 3
Permissible adjusting range
1
End position "Moved out"
2
End position "Moved in"
4.4.2
Adjustment of limit switches
CAUTION
Risk of damage to unit by incorrect limit switch adjustment.
• Before adjusting the limit switches, the piston rod must be moved several
centimetres away from the position to be set.
Factory setting:
The limit switches have been preset to the dimensions defined in the order con-
firmation.
If other dimensions are required, they can be readjusted within the permissible
adjusting range as described below.
25

Publicidad

loading

Este manual también es adecuado para:

Junior 1sJunior 2