Descargar Imprimir esta página

Nilfisk VHC200 Manual De Instrucciones página 31

Ocultar thumbs Ver también para VHC200:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Installation, cleaning and replacement of
the separator (optional)
Figure 12
[ NOTE ]
Instructions describing how to fit the optional kits and the
relative operation and maintenance manuals are supplied
together with the optional kits.
[ NOTE ]
If there is only a dust deposit on the separator (4) allow the
dust to drop through the central hole.
The separator (4) should first be disassembled in order to be
perfectly cleaned:
Release the closing hooks (1) of the cover (2) and remove
the cover.
Remove the filter.
Unscrew the two screws (3) and remove it from the
container.
Replace the part if it is excessively worn.
Reinstall the separator (4).
Lock it and fix it by means of the two screws (3).
Fit the filter back in place, close the cover (2) and lock it by
means of the two the closing hooks (1).
Tightness inspection
Hoses check
Figure 13
Make sure that connecting hoses (1) are in a good condition
and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are treated, check for possible clogging
along the hose, in the inlet and on the baffle plate inside the
filtering chamber.
To clean, scrape the inlet (2) from the outside to remove
deposits.
Filtering chamber gasket check for machines
equipped with dust container
Figure 14
If the gasket (1) between the container and the filtering chamber
(3) fails to guarantee sealing:
Loosen the four screws (2) that lock the filtering chamber
(3) against the vacuum cleaner structure.
Allow the filtering chamber (3) to lower down and tighten
the screws (2) once it has reached the sealing position.
If an optimal seal is not yet obtained or if there are tears, cracks,
etc., the gasket must be replaced.
13
VHC200
IT
GB
F
D
E
C385

Publicidad

loading